HIOKI CT6846A - AC/DC High-accuracy Current Clamp, 1000 A / 100 kHz
AC/DC current clamp, 1000 A rated current, bandwidth from DC to 100 kHz, zero-flux
principle with fluxgate, basic accuracy ±0.2 % rdg., conductor diameter up to 50 mm, cable
length 3 m, ME15W connector
Description
Product information HIOKI CT6846A - AC/DC High-accuracy Current Clamp, 1000 A / 100 kHz
Key Specifications
- AC/DC currents up to 1000 A
- Frequency Bandwidth DC to 100 kHz
- Basic accuracy: ±0.2% rdg.
- Operating temperature: -40 °C to 85 °C
- Output voltage ratio 2 mV/A
Typical Applications
- High-current measurements on battery main lines and drive systems up to 1000 A
- Heavy electric vehicles such as trucks and buses
- Measurements on larger cables and busbars with conductor diameters up to 50 mm
| Model | Rated current | Bandwidth | Max. conductor Ø | Basic accuracy |
|---|---|---|---|---|
| CT6847A | 2000 A DC / 1400 A AC | DC to 70 kHz | φ50 mm | ±0.15 % rdg. |
| CT6846A | 1000 A AC/DC | DC to 100 kHz | φ50 mm | ±0.2 % rdg. |
| CT6845A | 500 A AC/DC | DC to 200 kHz | φ50 mm | ±0.2 % rdg. |
| CT6844A | 500 A AC/DC | DC to 500 kHz | ||
| CT6843A | 200 A AC/DC | DC to 700 kHz | φ20 mm | |
| CT6841A | 20 A AC/DC | DC to 2 MHz |
Detailed Product Overview
Rated for currents up to 1000 A on conductors up to 50 mm, the HIOKI CT6846A AC/DC High-accuracy Current Clamp extends clamp-on measurement to high-current circuits. Its zero-flux fluxgate technology holds a basic accuracy of ±0.2 % rdg across both AC and DC, even when the temperature changes during the measurement, because the fluxgate element shows practically no drift. Its bandwidth from DC to 100 kHz also captures rapid current changes for precise current and power measurement on heavy vehicles and other highpower systems.It measures the high currents found on the battery main lines and drive systems of trucks,
buses, and other heavy electric vehicles, reaching conductor sizes beyond what the smaller
clamps in the series are built for. Even in cold climates or inside enclosed power electronics
housings, its -40 °C to 85 °C operating range keeps measurements possible.
Flexible connection to measurement systems
The CT6846A connects to HIOKI power analyzers such as the PW8001 and PW4001
through its ME15W connector, which carries the measurement signal and delivers the
sensor's power supply at the same time, so no separate supply is needed; the same direct
connection applies to the MR6000 Memory Recorder through the U8977 current unit.
Oscilloscopes and other DAQ systems connect instead through a HIOKI current sensor
interface (CT9555, CT9556, CT9557), which converts the ME15W signal to a BNC output
and supplies the sensor's power, at a voltage output ratio of 2 mV/A.
The CT6846A's 50 mm
opening also takes in the thick, rigid busbars and cables typical of heavy-vehicle drive
systems. For measurement points further from the instrument, such as in truck and bus
workshops or depots, the 3-meter cable can be extended to up to 10 m using two CT9902
extension cables.
The CT6846A's phase error scales as a fixed time delay rather than shifting with frequency,
which is why a single correction value is all HIOKI power analyzers such as the PW8001 and
PW4001 need to compensate it automatically, in the same way an oscilloscope's deskew
function keeps channels aligned. Current and voltage stay in step across the band as a
result, so power measurements remain accurate under high-frequency and low-power-factor
conditions.
Ready for high currents up to 1000 A
The CT6846A brings the series' high-current capability to circuits up to 1000 A, in the same
50 mm form factor as the CT6845A and CT6847A. Where currents exceed 1000 A, the
CT6847A continues the range in the identical form factor. Its zero-flux stability ensures
accurate measurement alike in workshops, depots, and the field.
More than specs – find more details here:
Zero-flux Current Clamps: Accuracy without effort from mA to kA
Measure Power with Precision – Across All Applications
What's in the Box
- CT6846A AC/DC Current Clamp
- Carrying Case
- Markup bands ×6
- Instruction Manua
Dimensions & Packaging
| Length | 238 mm |
|---|---|
| Width | 116 mm |
| Height | 35 mm |
| Weight | 0.99 kg |
-
Product catalog with data sheet, current sensors & current probes series (English)16,413 KB pdf
-
Product brochure with data sheet, Sensor Unit CT9555, CT9556, CT9557 (English)1,693 KB pdf
-
Product catalog, POWER ANALYZER Series (English)2,713 KB pdf
-
Product Catalog, Power Meter Series PW3335, PW3336, PW3337, 3333, 3334 (English)9,158 KB pdf
-
Instruction Manual, AC/DC CURRENT PROBE CT6846A (English)1,254 KB pdf
-
Instruction Manual, AC/DC CURRENT PROBE CT6841A CT6843A CT6844A CT6845A CT6846A CT6847A (Japanese, English, Chinese)5,978 KB pdf
-
Datasheet AC/DC High-accuracy Current Clamp CT6846A (English)2,075 KB pdf
-
Flyer, AC/DC CURRENT PROBE CT6841A, CT6843A, CT6844A, CT6845A, CT6846A (English)1,506 KB pdf
-
Flyer DATA CENTER TEST SOLUTION (English)2,015 KB pdf
How to Purchase Your HIOKI Products
Whether you order directly from HIOKI EUROPE or through an authorized distribution partner: choose the route that fits your procurement process. Our authorized HIOKI partners can assist locally with quotations and orders in your language.