CT6872 - AC/DC Current Sensor, 50 A / 10 MHz

Description

Product information CT6872 - AC/DC Current Sensor, 50 A / 10 MHz

The CT6872 is a high-precision AC/DC current sensor designed for detailed waveform observation and harmonic analysis. With a frequency range of up to 10 MHz, it is ideal for high-frequency power electronics testing. It supports automatic phase shift correction (APSC).

Technical Details:
  • Current Rating: 50 A AC/DC
  • Frequency Range: DC to 10 MHz
  • Accuracy: ±0.03% rdg, ±0.002% f.s.
  • Maximum Conductor Diameter: 24 mm
  • Operating Temperature: -40°C to 85°C
  • Input Impedance Requirement: 1 MΩ or higher

More than specs – find more details here:
Measure Power with Precision – Across All Applications
Skip product gallery

Related products

MR9000 - Printer module for MR8880-20 MR9000 - Printer module for MR8880-20
MR9000
MR9000 - Printer module for MR8880-20
The MR9000 Printer Unit is designed for use with the Hioki MR8880-20 Memory recorder, enabling easy printouts of measurement results. This compact and efficient printer offers precise waveform documentation directly from the connected Memory HiCorder, making it ideal for fieldwork and quick data review. The MR9000 ensures seamless integration with your HiCorder, delivering accurate and reliable outputs for all your measurement needs. Technical Information: Compatible devices: Hioki MR8880-20 Memory HiCorder Usable recording paper: 9234 Recording Paper Recording width: 104 mm (832-dot resolution), waveform section width 100 mmRecording speed: Max 1 cm/s Paper feed accuracy: ±3% (at 25°C, 60% RH)

Regular price: €668.00
9234 - Printer paper for MR8880-20, 8807/08, 8420 series HIOKI 9234 printer paper a6 for MR8880-20
9234
9234 - Printer paper for MR8880-20, 8807/08, 8420 series
The 9234 is a printerpaper for MR8880 (PRINTER UNIT MR9000 required) and 8860, 8861, 8420, 8421, 8422, 8807, 8808, 8714, 8715 memory recorders. Technical Details:Roll type A6 width 112 mm × 18 m 10 rolls/set

Regular price: €118.00
Z1002 - Power supply unit for MR8880, MR8875, PW3198
Z1002
Z1002 - Power supply unit for MR8880, MR8875, PW3198
Z1002 ist ein Universalnetzteil für Netzspannungen von 100 V bis 240 V AC, 50/60 Hz, das 12V DC, 5,25A max (63W) zur Verfügung stellt. Es ist geeignet für die Hioki-Produkte CT9557, MR8875, MR8880, PW3198, PQ3100, PQ3198.Technische Details: Eingangsbereich: 100VAC bis 240VAC Ausgang: 12VDC, 5,25A, Pmax 63W Restwelligkeit & Rauschen: 100mVpp DC-Stecker: gewinkelter Hohlstecker 5,5mm (Innenmaß 2,5mm)

Regular price: €168.00
L1012 - DC Power cable for LR8450, LR810x, MR8875 and MR8880
L1012
L1012 - DC Power cable for LR8450, LR810x, MR8875 and MR8880
DC Power cable, 2 m, unprocessed ends, for LR8450, LR8450-01, LR8101, LR8102, MR8875 and MR8880

Regular price: €48.00
HIOKI PW8001 - Modular 8-channel High Precision Power Analyzer HIOKI PW8001 high precision power analyzer plug and play connectivity with HIOKI current sensors
PW8001
HIOKI PW8001 - Modular 8-channel High Precision Power Analyzer
Modular high precision power analyzer, up to 8 channels, ±0.03% basic accuracy, 15 MHz sampling rate, 18-bit A/D conversion, automatic phase shift correction for Hioki current sensors, 1 ms data update rate, CMRR 110 dB @ 100 kHz

PW3390 - Portable 4-channel Power Analyzer PW3390 - Portable 4-channel Power Analyzer
PW3390
PW3390 - Portable 4-channel Power Analyzer
Portable 4-channel Power Analyzer, ±0.09% basic accuracy, DC to 200 kHz measurement band for power, 16-bit conversion, phase shift correction for HIOKI current sensors, 50 ms data update rate, 16-ch waveform/analog output, motor analysis function, WLTP compliant

PW3336 - AC/DC Power Meter PW3336 - AC/DC Power Meter
PW3336
PW3336 - AC/DC Power Meter
The PW3336 series measures power across a wide range of electrical equipment, from single-phase devices to industrial three-phase systems using 2 input channels.

Regular price: €4,058.00
C1004 - Carrying Case for MR8875
C1004
C1004 - Carrying Case for MR8875
Durable hard-shell case with wheels and telescoping handle, precisely fitted for MR8875 and accessories.

Regular price: €718.00
MR8902 - Input module for MR8875
MR8902
MR8902 - Input module for MR8875
The MR8902 Voltage/Temp Unit is a 15-channel voltage and thermocouple input module for the MR8875 memory recorder, designed for stable multi-point DC voltage and temperature acquisition in demanding industrial environments.Each of the 15 channels can be individually configured for voltage or thermocouple measurement. With 16-bit A/D conversion and ranges from 500 µV/div up to 5 V/div, the module enables precise low-level signal acquisition across a wide measurement span. Simultaneous channel scanning supports synchronized multi-point monitoring at update rates down to 10 ms. The unit supports thermocouple types K, J, E, T, N, R, S, B and W, with selectable internal or external reference junction compensation. Internal compensation accuracy is ±0.5°C (added to measurement accuracy). Thermocouple broken-wire detection is integrated and switchable. High noise immunity supports reliable operation in electrically demanding environments, with a normal mode rejection ratio of ≥50 dB and a common mode rejection ratio up to 140 dB (with digital filter). Selectable 50 Hz or 60 Hz digital filtering enhances measurement stability under industrial mains conditions. Typical applications include multi-channel temperature profiling, environmental and thermal validation testing, industrial DC signal monitoring, and long-term trend recording in laboratory and field environments. Technical specificationsChannels: 15 (voltage / thermocouple) Measurement: Voltage, temperature (thermocouple); types K, J, E, T, N, R, S, B, WRe5-26Range / resolution: 500 µV to 5 V/div, 16-bit A/DInput: Push terminal, 1 MΩUpdate rate: 10 ms, 20 ms, 500 ms, 2 s Filter: Digital filter 50 Hz, 60 Hz, OFF Accuracy: ±0.1 % f.s. Voltage limits: 100 V DC input, 100 V AC/DC to earth

Regular price: €1,738.00
Z1000 - Battery pack for MR8880 and LR8400 series
Z1000
Z1000 - Battery pack for MR8880 and LR8400 series
The Z1000 Battery pack is a NiMH type recharchable battery for the MR8880, LR8400 series products. It charges when installed in the main unit. Product details: Rating: 7.2V, 4500mAh Weight: 0.37 kg

Regular price: €308.00
MR8901 - Input module for MR8875 HIOKI MR8901 Input module for MR8875
MR8901
MR8901 - Input module for MR8875
The MR8901 Analog Unit is a 4-channel voltage input module for the memory recorder MR8875. It enables voltage measurement with simultaneous sampling across all channels. The module provides four isolated BNC input connectors with an input resistance of 1 MΩ and an input capacitance of 10 pF. It supports measurement ranges from 5 mV to 10 V/div with 11 selectable ranges. Simultaneous sampling at up to 500 kS/s across all channels allows acquisition of transient and dynamic signals. The frequency characteristics extend from DC to 100 kHz (–3 dB). The maximum allowable input voltage is 150 V DC, and the maximum rated voltage to earth is 100 V AC/DC.Typical applications include transient analysis, switching waveform recording, dynamic signal measurement, and multi-channel signal acquisition in laboratory and industrial environments. Technical specificationsNumber of channels: 4 (voltage measurement) Input connectors: Isolated BNC, 1 MΩ, 10 pFMeasurement range: 5 mV to 10 V/div (11 ranges) Sampling rate: 500 kS/s (simultaneous across all channels) Frequency characteristics: DC to 100 kHz (–3 dB)Maximum input voltage: 150 V DCMaximum rated voltage to earth: 100 V AC/DCLow-pass filter: 5 / 50 / 500 Hz, 5 kHz, OFF Input coupling: DC, GND Accuracy: ±0.5 % of full scale 

Regular price: €1,558.00
PW3337 - 3-channel AC/DC power meter up to 65 A and 1000 V PW3337 - 3-channel AC/DC power meter up to 65 A and 1000 V
PW3337
PW3337 - 3-channel AC/DC power meter up to 65 A and 1000 V
3-channel AC/DC Power Meter, voltage up to 1000 V, direct current input up to 65 A without internal shunts, 5000 A via external sensors, frequency bandwidth DC to 100 kHz, IEC 61000-4-7 harmonic analysis, LAN and RS-232C interface

Regular price: €5,598.00
CT9902 - EXTENSION CABLE
CT9902
CT9902 - EXTENSION CABLE
The HIOKI CT9902 is a 5-meter extension cable designed for use with ME15W-equipped current transformers (CTs), providing additional length for versatile installations. 

Regular price: €248.00
MR8880 - Portable Memory Recorder, 4 Channels MR8880 - Portable Memory Recorder, 4 Channels
MR8880-20
MR8880 - Portable Memory Recorder, 4 Channels
The MR8880 is a 4 channel portable data acquisition system (DAQ) with a maximum sampling rate of 1Msamples/s on all analog channels simultaneously. It has 4 analog direct input channels for voltages up to 600V and 8 logic channels.Technical Details: Complies CAT III 600V isolation for direct measure of 480V power line 4 complete isolated channels Operating temperature range of -10°C to 50°C Built to withstand mechanical shocks and vibrations PRESET function A memory capacity of 14bit × 1 M words/ch (1 word = 2 bytes)

Regular price: €3,278.00
MR8875 - Portable memory recorder MR8875 - Portable memory recorder
MR8875
MR8875 - Portable memory recorder
The Hioki MR8875 Memory Recorder is a high-speed, multi-channel logger designed for long-term data recording and real-time waveform monitoring. It supports various input modules for mixed signal measurement, including voltage, temperature, strain, and CAN signals, with a sampling period as short as 2 µs. Its robust design is suitable for harsh environments, making it ideal for applications such as battery evaluation, motor testing, and power equipment analysis. Technical Details: Channels: Up to 60 channels with input modulesSampling Rate: 500 kS/sMemory Capacity: 32 MW (64 MB) Display: 8.4-inch TFT color LCD Storage: SD card, USB memory stick Dimensions: 298 mm × 224 mm × 84 mmWeight: 2.4 kg (excluding modules)

Regular price: €4,998.00
MR8904 - Input module for MR8875 HIOKI MR8904 dual port can input module for MR8875
MR8904
MR8904 - Input module for MR8875
The MR8904 CAN Unit is a 2-port CAN interface module for the memory recorder MR8875. It enables acquisition and output of CAN communication signals. The module supports CAN communication according to ISO 11898 and SAE J2411 standards. Each port can be configured for high-speed CAN, low-speed CAN, or single-wire CAN. CAN messages can be received and transmitted, and acknowledgment settings can be configured. Received CAN signals can be converted into analog or logic channels for recording. Up to 15 analog channels (16-bit equivalent) and 16 logic channels can be output. Signal mapping depends on bit length.The module provides ID-trigger functionality and outputs a pulse signal when a specified CAN ID is received. Response time is within 200 μs after message reception.Typical applications include CAN bus monitoring, signal analysis, and synchronized recording of communication data in laboratory and industrial environments. Technical specifications CAN ports: 2 (D-sub, 9-pin)Standards: ISO 11898 (CAN 2.0b), ISO 11898-1/-2/-3, SAE J2411 Interface: High-speed CAN, low-speed CAN, single-wire CAN (per port selectable)Baud rate: 50 kbps to 1 Mbps (high-speed), 10 kbps to 125 kbps (low-speed), 10 kbps to 83.3 kbps (single-wire) Signal output: up to 15 analog channels (16-bit equivalent), 16 logic channels Signal mapping: 1 to 32-bit signals (channel allocation depending on bit width)ID trigger: pulse output on logic channelResponse time: ≤200 μsTerminator: 120 Ω ±10 %, switchableACK control: ON/OFF 

Regular price: €2,388.00
MR8905 - Input module for MR8875 MR8905 - Input module for MR8875
MR8905
MR8905 - Input module for MR8875
The MR8905 Analog Unit is a 2-channel voltage input module for the memory recorder MR8875. It enables voltage measurement of instantaneous values and AC RMS values. Each channel supports measurement ranges from 500 mV to 50 V/div. The module uses 16-bit A/D conversion and supports simultaneous sampling across both channels at up to 500 kS/s. The frequency characteristics extend from DC to 100 kHz (–3 dB).The module supports RMS measurement with defined accuracy and response time. Input coupling modes DC, AC-RMS, and GND are selectable. The maximum allowable input voltage is 1000 V DC or 700 V AC. The maximum rated voltage to earth is CAT II 1000 V AC/DC and CAT III 600 V AC/DC. Typical applications include voltage measurement, RMS evaluation, and waveform analysis in laboratory and industrial environments. Technical specifications Channels: 2 (voltage, instantaneous / AC RMS selectable) Input: banana connector, 4 MΩ, <1 pFMeasurement range: 500 mV to 50 V/divAccuracy: ±0.5 % f.s. (instantaneous), ±1.5 % / ±3 % f.s. (RMS, frequency-dependent) Sampling / resolution: 500 kS/s simultaneous, 16-bit (1/1250) Frequency characteristics: DC to 100 kHz (–3 dB) Low-pass filter: 5, 50, 500 Hz, 5 kHz, OFF Input coupling: DC, AC-RMS, GNDMaximum input: 1000 V DC, 700 V AC Maximum rated voltage to earth: CAT II 1000 V AC/DC, CAT III 600 V AC/DC 

Regular price: €1,558.00
CT9555 - Current Sensor Interface, 1-Channel CT9555 - Current Sensor Interface, 1-Channel
CT9555
CT9555 - Current Sensor Interface, 1-Channel
1 channel current sensor interface for current sensors, clamps and probes with ME15W connectors, sensor power supply, BNC waveform output

Regular price: €508.00
CT9556 - Current Sensor Interface, 1-Channel, with RMS Output CT9556 - Current Sensor Interface, 1-Channel, with RMS Output
CT9556
CT9556 - Current Sensor Interface, 1-Channel, with RMS Output
1 channel current sensor interface for current sensors, clamps and probes with ME15W connectors, sensor power supply, BNC waveform output, BNC RMS output

Regular price: €668.00
MR8903 - Input module for MR8875 MR8903 - Input module for MR8875
MR8903
MR8903 - Input module for MR8875
The MR8903 Strain Unit is a 4-channel strain and low-voltage input module for the memory recorder MR8875. It enables strain and voltage measurement with configurable inputs for each channel.Each channel can be configured for strain gauge or low-level voltage measurement. The module uses 16-bit A/D conversion and supports simultaneous sampling across all channels at up to 200 kS/s. The frequency characteristics extend from DC to 20 kHz. The strain measurement function supports bridge sensors from 120 Ω to 1 kΩ with a bridge excitation voltage of 2 V. Measurement ranges span from 20 µε/div to 1000 µε/div. Selectable low-pass filters (5 Hz, 10 Hz, 100 Hz, 1 kHz, OFF) are available. The maximum allowable voltage between input terminals and earth is 30 V AC rms or 60 V DC. The maximum bridge input voltage is 10 V DC. Typical applications include strain measurement, vibration analysis, and multi-channel data acquisition in laboratory and industrial environments. Technical specificationsChannels: 4 (strain/voltage selectable per channel, auto-balance ±10000 με) Input: ≥1 MΩ, bridge 120 Ω to 1 kΩ, excitation 2 V ±0.05 VMeasurement ranges: 20–1000 με/div (strain), 50–1000 μV/div (voltage) Accuracy: ±0.5 % f.s. (range-dependent, incl. offset) Sampling / resolution: 200 kS/s simultaneous, 16-bit (1/1250)Frequency characteristics: DC to 20 kHz (+1/−3 dB)Low-pass filter: 5, 10, 100 Hz, 1 kHz, OFF Maximum voltage: 10 V DC input, 30 V AC rms / 60 V DC to earth 

Regular price: €3,568.00
Z1003 - Battery pack for MR8875, PW3198
Z1003
Z1003 - Battery pack for MR8875, PW3198
The Z1003 is a 7.2 V DC, 4500mAh Nickel-Metal Hydride (Ni-MH) rechargeable battery pack designed for use with Hioki devices such as the MR8875, PQ3198/PW3198, and PQ3100. It provides reliable power, ensuring extended operation in the field and in demanding environments. Technical Details: Battery Type: Ni-MH Voltage: 7.2 V DC Capacity: 4500mAh Compatible Devices: MR8875, PQ3198/PW3198, PQ3100

Regular price: €178.00
CT9557 - Current Sensor Interface, 4-Channel CT9557 - Current Sensor Interface, 4-Channel
CT9557
CT9557 - Current Sensor Interface, 4-Channel
4 channel current sensor interface for current sensors, clamps and probes with ME15W connectors, sensor power supply, 4 ch BNC waveform outputs, BNC total waveform output, BNC total RMS output

Regular price: €1,618.00
HIOKI L9217 bnc cable insulated 1,6 m insulated bnc connectors
L9217
L9217 - BNC Cable, Insulated, 1.6 m
Insulated BNC cable, BNC plugs on both ends, plastic connector housings, ferrite for noise suppression, 1.6 m cable length, rated voltage 300 V, CAT III 300 V / CAT II 600 V, made in Japan

Regular price: €78.00
HIOKI LR8102 - Modular multi-channel Data Logger for system integration, optical sync, UDP, CAN HIOKI LR8102 modular multi-channel data logger real time data transfer via udp
LR8102
HIOKI LR8102 - Modular multi-channel Data Logger for system integration, optical sync, UDP, CAN
Main unit for system integration applications, modular system, max. 3000 voltage/temperature channels or 120 power channels, for high voltage/high current applications, real-time data transfer via UDP, max. update interval 5 ms, for 19” rack systems

LR8101 - Modular multi-channel Data Logger for system integration LR8101 - Modular multi-channel Data Logger for system integration
LR8101
LR8101 - Modular multi-channel Data Logger for system integration
Main unit for system integration applications, modular system, max. 300 voltage/temperature or 12 power channels, for high voltage/high current applications, max. update interval 5 ms, for 19” rack systems

Regular price: €2,168.00