Z1008 - AC Adapter for LR853x modules, P9000, SP700x, PW3365

AC Adapter, 100 V to 240 V AC, 50/60 Hz, for LR853x modules, P9000, SP700x, PW3365

Product information "Z1008 - AC Adapter for LR853x modules, P9000, SP700x, PW3365"

The Z1008 AC Adapter provides a reliable power supply for compatible devices. Designed to operate with a rated supply voltage of 100 V to 240 V AC (±10% voltage fluctuation) and a power supply frequency of 50 Hz/60 Hz, it ensures stable performance across various environments. 

The Z1008 can be used to provide power to the LR853x modules of the LR8450 Data Logger series, P9000-01, P9000-02, SP7001, SP7002, and PW3365. It is already included as a standard accessory with these devices but can be ordered separately if a replacement is needed.

Technical Details: 
  • AC Inlet: IEC-60320-C14 
  • Input range: 100VAC to 240VAC 
  • Output: 12VDC, 1.25A, Pmax 15W 
  • Ripple & Noise: 100mVpp 
  • DC plug: angled EIAJ-4 plug O.D. 5.5mm, I.D. 3.3mm 
  • Z1008 AC Adapter

Related products

LR8530
LR8530 - 15-ch wireless logger module for voltage and temperature, 10 ms
15-channel wireless interface module for LR8450-01 Data Logger, update interval 10 ms, for DC voltage and temperature, 16 bits, 100 V direct input, 300 V isolation, AC or battery operation, M3 screw terminal block

€1,358.00*
LR8531
LR8531 - 15-ch wireless logger module for voltage, temperature and resistance, 10 ms
15-channel wireless interface module for LR8450-01 Data Logger, update interval 10 ms, for DC voltage, temperature, humidity and resistance, 16 bits, 100 V direct input, 300 V isolation, AC or battery operation, spring-cage terminal block

€1,618.00*
LR8532
LR8532 - 30-ch wireless logger module for voltage and temperature, 10 ms
30-channel wireless interface module for LR8450-01 Data Logger, update interval 10 ms, for DC voltage and temperature, 16 bits, 100 V direct input, 300 V isolation, AC or battery operation, spring-cage terminal block

€1,948.00*
LR8533
LR8533 - 5-ch wireless logger module for voltage, 1 ms
5-channel wireless interface module for LR8450-01 Data Logger, update interval 1 ms, for DC voltage, 16 bits, 100 V direct input, 300 V isolation, AC or battery operation, M3 screw terminal block

€1,588.00*
LR8534
LR8534 - 5-ch wireless logger module for strain gauges, 1 ms
5-channel wireless interface module for LR8450-01 Data Logger, update interval 1 ms, for strain gauges, 16 bits, 1/2/4-gauge method, AC or battery operation, spring-cage terminal block

€2,718.00*
LR8535
LR8535 - Wireless logger module CAN and CAN FD signals, 10 ms
Wireless interface module for LR8450-01 Data Logger, update interval 10 ms, for CAN and CAN FD signals input, 2 ports, max. 500 channels, AC or battery operation, D-sub 9-pin male connectors

€2,688.00*
LR8536
LR8536 - 5-channel wireless logger module for current sensors, 1 ms
5-channel wireless interface and signal conditioning module for the LR8450-01 Data Logger to connect HIOKI Current Sensors with a PL14 connector

€1,858.00*
P9000-02
P9000-02 - Differential probe
The Differential Probe P9000-02 combines waveform monitoring with AC RMS value output, offering increased versatility for high-voltage applications. With the capability to monitor waveforms and RMS values, it is suitable for industrial applications such as electric vehicle battery circuits, solar power systems, and commercial high-voltage circuits. The probe is lightweight, compact, and offers high accuracy across a wide range of operating temperatures, ensuring durability and performance in demanding conditions. Technical Specifications: Measurement Functions: Waveform monitor output and AC RMS value output (switchable) Frequency Characteristics (Wave Mode): DC to 100 kHz, -3 dB Frequency Characteristics (RMS Mode): 30 Hz to 10 kHz RMS Amplitude Accuracy: ±1% f.s. (30 Hz to 1 kHz); ±3% f.s. (1 kHz to 10 kHz) Response Time (RMS Mode): 300 ms (rising), 500 ms (falling) Division Ratio: 1000:1 or 100:1 (user selectable) DC Amplitude Accuracy: ±0.5% f.s. Input Resistance and Capacity: 10.5 MΩ, 5 pF or less (at 100 kHz) Maximum Allowable Input: 1000 V AC/DC Max. Rated Voltage to Earth: 1000 V AC/DC (CAT III) Operating Temperature Range: -40°C to 80°C Power Supply Options: o AC Adapter (Z1008), USB, External DC (2.7V to 15V DC) Dimensions: 128 mm (W) × 36 mm (H) × 22 mm (D) Mass: 170 g Cord Length: Input 70 cm; Output 1.5 m

€608.00*
P9000-01
P9000-01 - Differential probe
The Differential Probe P9000-01 is designed to offer superior flexibility for waveform monitoring in high-voltage environments. Ideal for use with Hioki Memory Reorders and Dataloggers, it allows accurate and reliable measurement in various industrial applications, such as electric vehicles, solar power systems, and commercial power circuits. Compact and lightweight, this probe offers 1000 V AC/DC measurements with a choice between 1000:1 and 100:1 division ratios. With a robust operating temperature range, it ensures performance even in challenging conditions. Technical Specifications: Measurement Functions: Waveform monitor output only Frequency Characteristics (Wave Mode): DC to 100 kHz, -3 dB Division Ratio: 1000:1 or 100:1 (user selectable) DC Amplitude Accuracy: ±0.5% f.s. Input Resistance and Capacity: 10.5 MΩ, 5 pF or less (at 100 kHz) Maximum Allowable Input: 1000 V AC/DCMax. Rated Voltage to Earth: 1000 V AC/DC (CAT III) Operating Temperature Range: -40°C to 80°CPower Supply Options: o AC Adapter (Z1008), USB, External DC (2.7V to 15V DC)Dimensions: 128 mm (W) × 36 mm (H) × 22 mm (D) Mass: 170 g Cord Length: Input 70 cm; Output 1.5 m

€478.00*
SP7001-90
SP7001-90 - Non-contact CAN FD/CAN sensor
The SP7001-90 Non-Contact CAN Sensor allows for safe, efficient data acquisition from CAN and CAN FD networks without modifying or damaging the wiring. Designed for automotive development, the SP7001-90 simplifies capturing CAN signals, even in tight spaces, by clipping directly onto the CAN bus cables. This innovative sensor features a capacitive coupling method, ensuring that the CAN bus's electrical characteristics remain unaffected, which is crucial for secure testing and real-time monitoring of vehicle systems. It supports communication speeds up to 3 Mbit/s, making it ideal for advanced driver assistance systems (ADAS) and autonomous driving applications. Technical Details: Measurement Method: Non-contact, capacitive coupling Supported Protocols: CAN, CAN FD Communication Speed: 125 kbit/s to 3 Mbit/s (CAN FD)Operating Temperature Range: -40°C to 85°C Maximum Rated Voltage: 300 V AC/DC (terminal-to-ground) Power Supply: External power supply (10 V to 30 V DC) or Z1008 AC Adapter Dimensions: 44 mm (W) × 85 mm (H) × 20 mm (D) Weight: Approx. 180 g Output Connector: D-sub 9-pin female

€2,668.00*
SP7002-90
SP7002-90 - Non-contact CAN sensor
The SP7002-90 Non-Contact CAN Sensor allows for safe and efficient data acquisition from CAN networks without the need for direct contact with or modification of the wiring. Designed for automotive testing, the SP7002-90 captures CAN signals with ease, even in tight and complex wiring environments. Its non-intrusive design ensures the integrity of the CAN bus during data capture, making it ideal for vehicle diagnostics and real-time monitoring. The sensor supports communication speeds up to 1 Mbit/s and operates reliably across a wide temperature range, making it suitable for both lab and field environments. Technical Details: Measurement Method: Non-contact, capacitive couplingSupported Protocols: CANCommunication Speed: 125 kbit/s to 1 Mbit/s Operating Temperature Range: -40°C to 85°C Maximum Rated Voltage: 300 V AC/DC (terminal-to-ground)Power Supply: External power supply (10 V to 30 V DC) or Z1008 AC Adapter Dimensions: 44 mm (W) × 85 mm (H) × 20 mm (D) Weight: Approx. 180 g Output Connector: D-sub 9-pin female

€2,098.00*
PW3365-20
PW3365 - Non-contact power logger with voltage and current sensors
Non-contact 3-phase 4-wire Clamp-on Power Logger, 90 V to 520 V at 50/60 Hz, 50 mA to 5 kA using external current sensors, harmonic measurement up to the 13th order, SD memory card slot (max. 8 GB), LAN and USB interface