SP7002-90 - Non-contact CAN Sensor Set, screw type probes, up to 2 CAN buses

Non-contact CAN sensor set, screw type probes, for 1 CAN bus (expandable to 2), 125 kbit/s to 1 Mbit/s, Vector-compatible D-sub output, DC powered, includes SP7002 sensor, SP9200 probes, and SP7100 interface

Product information SP7002-90 - Non-contact CAN Sensor Set, screw type probes, up to 2 CAN buses


Key Specifications

  • Signal detection: Capacitive, non-contact, screw type probes (no bare-wire connection) 
  • Number of CAN buses: 1 bus, expandable to 2 
  • Communication speed: 125 kbit/s to 1 Mbit/s (CAN) 
  • Output connector: D-sub 9-pin (female, Vector-compatible / direct connection to PW4001) 
  • Power supply: 10 to 30 V DC 

Unique Advantages

  • Enables CAN signal acquisition without stripping cable insulation 


Typical Applications

  • Non-contact signal capture on in-vehicle CAN buses without cable modification 
  • Testing of production vehicles and prototypes without altering wiring 
  • Monitoring of secured or safety-critical ECUs without triggering lockouts
  • Power analysis with PW4001 Power Analyzer using CAN-based voltage data combined with current sensors 

Detailed Product Overview

The HIOKI SP7002-90 CAN Sensor Set enables non-intrusive measurement of standard CAN signals in long-term or in-vehicle testing environments. It combines the SP7002 noncontact CAN sensor, a pair of SP9200 screw-type signal probes, and the SP7100 CAN interface to provide stable and vibration-resistant signal acquisition without modifying vehicle wiring. Using capacitive coupling, the two SP9200 probes are fixed onto the insulated CAN H and CAN L lines to detect differential signals through the cable sheath. This method enables accurate, real-time signal acquisition without galvanic contact or interference with the circuit, eliminating the need for wire stripping or connector access and minimizing the risk of short circuits, connector wear, and induced noise. Because the sensor does not alter bus characteristics, it avoids triggering ECU lockouts, allowing safe observation of communication within fully assembled vehicles. 

Screw type probes and Vector compatibility

The SP9200 screw-type probes can be securely fixed to the cable by tightening the screw mechanism, ensuring a stable capacitive coupling that resists vibration and mechanical stress. This makes the configuration suitable for long-term or on-road testing where reliable signal acquisition is required. 

The SP7100 CAN interface reconstructs the detected signal and outputs it through a 9-pin Dsub connector compatible with Vector Informatik interfaces and the HIOKI PW4001 Power Analyzer. This allows direct connection to CAN analysis tools or to the PW4001 without additional adapters. Powered from a 10 to 30 V DC supply, the SP7100 provides two input channels for simultaneous monitoring of up to two independent CAN buses. It supports communication speeds from 125 kbit/s to 1 Mbit/s (CAN only), maintaining precise timing and waveform integrity. 

In the SP7002-90 set, one SP7002 sensor and one pair of SP9200 probes are included, allowing measurement of a single CAN bus. The second input can be used by adding an additional SP7002 and either an SP9200 screw-type or SP9250 clamp-type probe set. 

Power analysis with PW4001

When connected to the HIOKI PW4001 Power Analyzer, the SP7002-90 provides CANbased voltage data synchronized with current measurements from external current sensors. This configuration enables accurate power calculation on high-voltage systems without direct connection to battery terminals, improving operator safety and test efficiency. To interpret or decode CAN data, the user must provide a DBC (Database Container) file containing the identifiers and scaling parameters of the required signals. The PW4001 uses this information to extract the correct voltage value from the CAN data stream and combine it with the simultaneously measured current for precise power analysis. 

The SP7002-90 can be used independently with Vector-compatible systems or other CAN analysis tools. In combination with the HIOKI PW4001 Power Analyzer, it forms a safe, fast, and reliable solution for non-intrusive CAN signal acquisition and power analysis throughout the automotive development process.
  • SP7002 CAN Sensor 
  • SP9200 Screw Type Signal Probes (set of 2)
  • SP7100 CAN Interface 2CH 
  • L9500 Power Cable 
  • GND Connection Cable (1.5 m) 
  • Alligator clip, Quick Start Manual, Operating Precautions

Related products

SP7001-90
SP7001-90 - Non-contact CAN/CAN FD Sensor Set, screw type probes, up to 2 CAN buses
Der HIOKI SP7001-90 Non-Contact CAN Sensor ermöglicht eine sichere und effiziente Datenerfassung von CAN- und CAN FD-Netzwerken, ohne dass Kabel beschädigt oder verändert werden müssen.

€2,668.00*
PW4001
PW4001 - 4-channel Power Analyzer
Portable 4-channel power analyzer with ±0.04% basic accuracy, DC to 600 kHz frequency bandwidth, CAT II 1500 V DC, 1 ms data update rate, waveform & D/A output, motor analysis, external DC power input
LR8450
LR8450 - Modular multi-channel Data Logger
Multi-channel data logger, connect up to 4 plug-in modules with up to 120 analog channels, max. 1 ms update interval, max. 100 VDC, 8 inputs for pulse/logic/rotational speed, 7“ TFT-Display, GigabitLAN und USB / SD card, optional battery operation.

€1,818.00*
LR8450-01
LR8450-01 - Wireless modular multi-channel Data Logger
WLAN-enabled multi-channel data logger with up to 4 plug-in and 7 WLAN modules (maximum 330 channels), 1 ms sampling interval, 100 VDC, 8 inputs for pulse/logic/rotational speed, 7″ TFT display, Gigabit LAN, USB/SD, optional battery operation.

€2,158.00*
U8555
U8555 - Logger module for CAN and CAN FD signals, 10 ms
Plug-in interface module for LR8450 Data Logger Series, update interval 10 ms, for CAN and CAN FD signals input and output, 2 ports, max. 500 channels, D-sub 9-pin male connectors

€2,158.00*
LR8535
LR8535 - Wireless logger module CAN and CAN FD signals, 10 ms
Wireless interface module for LR8450-01 Data Logger, update interval 10 ms, for CAN and CAN FD signals input, 2 ports, max. 500 channels, AC or battery operation, D-sub 9-pin male connectors

€2,688.00*
SP7150
SP7150 - Single-channel CAN/CAN FD Interface for Non-Contact Signal Acquisition
Die HIOKI SP7150 CAN-Schnittstelle ist eine kompakte Lösung zur Verbindung der berührungslosen CAN-Sensoren von HIOKI, wie dem SP7001-95, mit CAN-Analysesystemen.

€1,068.00*
Z1008
Z1008 - AC Adapter for LR853x modules, P9000, SP700x, PW3365
AC Adapter, 100 V to 240 V AC, 50/60 Hz, for LR853x modules, P9000, SP700x, PW3365

€128.00*
C1013
C1013 - CARRYING CASE
Protective case for SP7001, SP7002, SP7100, SP9200 and accessories

€248.00*