DAQ Solutions: HIOKI Data Loggers & Memory Recorders
Reliable Measurement of Voltage, Current, Temperature, and More
HIOKI data loggers and recorders enable fast, multi-channel measurement in development, validation, and system monitoring.
Whether capturing voltage, current, temperature, strain, or humidity, the lineup includes modular, wireless, and portable solutions for a wide range of applications. Explore HIOKI’s scalable solutions for precise data logging and signal recording.
The MR6000 Memory Recorder delivers up to 200 MS/s and 32 channels for detailed waveform analysis. The LR8450 Wireless Data Logger is a versatile all-in-one system for multi-parameter testing, offering wireless expansion for voltage, current, temperature, and strain — ideal for flexible use in the lab or field. The LR8102 supports up to 3,000 temp/voltage channels and up to 120 power/current channels with system synchronization.
Multi-channel data logger, connect up to 4 plug-in modules with up to 120 analog channels, max. 1 ms update interval, max. 100 VDC, 8 inputs for pulse/logic/rotational speed, 7“ TFT-Display, GigabitLAN und USB / SD card, optional battery operation.
Modular memory recorder, up to 32 channels, max. sampling rate 200 MS/s, max 1000 VDC isolated direct voltage input, up to 1 TB storage with SSD option, intuitive user interface, touchscreen, real-time waveform calculation and real-time saving
Main unit for system integration applications, modular system, max. 3000 voltage/temperature channels or 120 power channels, for high voltage/high current applications, real-time data transfer via UDP, max. update interval 5 ms, for 19” rack systems
U8330 is an optional SSD storage unit for the HIOKI MR8827 Memory Recorder and is used to store measurement data, waveforms, instrument settings, screen images and calculation results. It is installed and formatted at the factory and must therefore be ordered as an option together with the Memory Recorder.
For U8330, the recommended replacement cycle is approx. 20,000 hours with continuous writing. The data retention time when the instrument is switched off is approx. 1 year. Technical specifications internal 128 GB SSD (MLC), FAT32 factory-installed option for MR8827, must be ordered together with the Memory Recorder recommended replacement cycle: approx. 20,000 hours with continuous writing, write capacity approx. 60 TB at 25 °C 1-year warranty Compatible Memory RecordersMR8827
Main unit for system integration applications, modular system, max. 300 voltage/temperature or 12 power channels, for high voltage/high current applications, max. update interval 5 ms, for 19” rack systems
Power measurement module for LR8101 and LR8102 Data Logger, up to 1500 VDC, CATII and 2000 A, 3 power channels, max. update interval 5 ms, DC to 100 kHz
Voltage/temperature module for LR8101 and LR8102 Data Logger, isolation to earth 600 VDC CATII, 30 channels, max. update interval 10 ms, for 19” rack systems