PW3360-20 - Compact Three-Phase Power Logger
Portable 3-phase 4-wire Clamp-on Power Logger, voltage range 600 V, current measurement with external sensors, ranges from 50 mA up to 5 kA, frequency measurement 40 to 70 Hz, with SD card slot, LAN and USB
Available stock:
2
Product details
Product number:
PW3360-20
EAN:
4536036001347
Width:
500 mm
Height:
1000 mm
Weight:
1.66 kg
Product information PW3360-20 - Compact Three-Phase Power Logger
Banner Specs
- 0.4% active power accuracy (without current sensor)
- 90 V to 780 V AC effective voltage range
- 50 mA to 5 kA effective current measurement range
- Long-term stand-alone logging to SD card
- Battery or DC powered
Applications
- Energy Efficiency Optimization
- Long-term power consumption monitoring
- Equipment diagnostics and checks
- Energy Audits
In detail:
The HIOKI PW3360-20 is a portable three-phase power and energy logger covering 90 V to 780 V AC at 50/60 Hz. It supports measurements from single-phase 2-wire to three-phase 4- wire systems and is suitable for use in factories, commercial buildings, and residential facilities. The built-in SD card slot supports memory cards up to 8 GB, enabling stand-alone logging of power usage and demand over extended periods.
The HIOKI PW3360-20 is a portable three-phase power and energy logger covering 90 V to 780 V AC at 50/60 Hz. It supports measurements from single-phase 2-wire to three-phase 4- wire systems and is suitable for use in factories, commercial buildings, and residential facilities. The built-in SD card slot supports memory cards up to 8 GB, enabling stand-alone logging of power usage and demand over extended periods.
The logger provides high-precision readings with a basic accuracy of ±0.4% for active power
(excluding current sensor accuracy). This accuracy enables reliable evaluation of power
consumption and supports the identification of potential energy losses and efficiency
improvements.
To perform measurements, the PW3360-20 requires AC current sensors with a BNC
connector. These current sensors are not included with the logger and must be ordered
separately.
The following Hioki current sensors are compatible with the PW3360-20:
Model | Load current Leak current | Leak current | |||||
---|---|---|---|---|---|---|---|
9660 | 9661 | 9669 | 9694 | CT9667 | 9657-10 | 9675 | |
Description | AC Clamp-on Sensor 100 A | AC Clamp-on Sensor 500 A | AC Clamp-on Sensor 1000 A | AC Clamp-on Sensor 5 A | AC Flexible Current Sensor 5000 A | AC Clamp-on leak sensor 10 A | AC Clamp-on leak sensor 10 A |
Bandwidth | 40 Hz bis 5 kHz | 10 Hz bis 20 kHz | 40 Hz bis 5 kHz | ||||
Rated current | 100 A | 500 A | 1000 A | 5 A | 500 A / 5000 A | 10 A | |
Output rate | 1 mV/A | 0.5 mV/A | 10 mV/A | 1 mV/A (500 A) 0.1 mV/A (5000 A) |
100 mV/A | ||
Basic accuracy | ±0.3% / ±1.0% | ±1.0% | ±0.3% | ±2.0% | ±1.0% | ±1.0% | |
Max. core diameter | 15 mm | 46 mm | 55 mm | 15 mm | 100 mm bis 254 mm | 40 mm | 30 mm |
By selecting the appropriate sensor, users can match the measurement range to their
specific monitoring needs, from low currents to several kiloamperes.
The PW3360-20 can log both load current and leak current, supporting both energy usage
analysis and electrical safety checks. Load current logging helps measure the consumption
of machines, panels, or entire facilities and makes it possible to identify inefficiencies to
optimize energy usage. Leak current logging detects unintended electrical leakage, which
may indicate insulation degradation, faulty wiring, or aging equipment. Monitoring leakage
current is important to prevent hazards, reduce fire risk, and ensure compliance with safety
standards. Together, these functions help identify inefficiencies and potential faults before
failures occur, enhancing overall system reliability and safety.
The included Z1006 AC adapter enables operation from a standard power outlet. If no outlet
is available, the instrument can alternatively be powered by the optional PW9002 Battery Set
or the optional PW9003 Voltage Line Power Adapter. The PW9002 attaches to the back of
the unit and provides up to 6 hours of operation when fully charged. The PW9003 is
connected separately to the line under test and supplies the instrument directly from it,
ensuring continuous operation as long as the line remains powered. These flexible options
ensure reliable operation in both fixed installations and mobile field use.
This power logger is designed for energy consultants, facility managers, and service
engineers as a reliable and safe solution for energy monitoring. Its compact design allows
installation even in confined spaces such as switchboards and connection cabinets. The
device supports real-time monitoring via LAN and connects to the free HIOKI Gennect One
PC software for continuous energy monitoring. Whether for one-time audits or long-term
monitoring, the PW3360-20 delivers precise data to support energy savings and improve
operational efficiency.
For users who also need harmonic analysis, the extended PW3360-21 model is available.
- PW3360-20 Three-Phase Power Logger
- Voltage cord set L9438-53
- AC adapter Z1006
- USB A to USB mini-B cable
- Instruction manual
- Measurement guide
- 2 color clip set (red, yellow, blue, white)
- 5 spiral tubes for grouping clamp sensor cords
- Application Software CD (SF4000 GENNECT One)
-
Product brochure with data sheet, clamp on power logger PW3360 (English)4,791 KB pdf
-
Product Catalog with data sheet, Field Measuring Instruments (English)40,026 KB pdf
-
Product catalog with datasheet, Selection guide, Power Quality Analyzers / Power Loggers (English)3,584 KB pdf
-
Instruction Manual, CLAMP ON POWER LOGGER PW3360 (English)6,876 KB pdf
-
Instruction Manual, CLAMP ON POWER LOGGER PW3360 (English)6,758 KB pdf
-
Product brochure with data sheet, AC FLEXIBLE CURRENT SENSOR CT9667 (English)1,746 KB pdf