9675 - Precision AC clamp leak current sensor, 10 A, 40 Hz to 5 kHz

AC clamp sensor, rated current 10 A, frequency range 40 Hz–5 kHz, amplitude accuracy (45-66 Hz): ±1.0 % rdg., phase accuracy (50/60 Hz) ±5°, conductor diameters up to 30 mm, CAT III 300 V, isolated BNC output

Product information 9675 - Precision AC clamp leak current sensor, 10 A, 40 Hz to 5 kHz

Banner Specs
  • Rated current 10 A AC 
  • Frequency characteristics (40 Hz to 5 kHz): ± 5% 
  • Amplitude accuracy (45-66Hz): ±1.0 % rdg.
  • Phase accuracy: ±5° (at 50 Hz or 60 Hz) 
  • Max. conductor diameter: 30 mm
  • Cable and connector: length approx. 3 m, isolated BNC connector 

Applications
  • Leakage current test of earthing conductors
  • Testing for insulation faults

In Detail:
The Hioki 9675 is a robust and compact AC current sensor designed for measuring small alternating and leakage currents up to 10 A. It offers amplitude accuracy (45–66 Hz) of ±1.0% of reading and phase accuracy of ±5° at 50 or 60 Hz. The sensor is suitable for fixed installation in control cabinets or distribution panels as well as for on-site measurements at the device under test. Measurement values can be recorded using loggers such as the LR5051 or LR8513, or energy loggers such as the PW3360 and PW3365.
  • 9675 Clamp On Leak Sensor
  •  Instruction Manual

Zugehörige Produkte

PW3360-20
PW3360-20 - Compact Three-Phase Power Logger
Portable 3-phase 4-wire Clamp-on Power Logger, voltage range 600 V, current measurement with external sensors, ranges from 50 mA up to 5 kA, frequency measurement 40 to 70 Hz, with SD card slot, LAN and USB

€1,248.00*
PW3365-20
PW3365 - Compact Three-Phase Power Logger with non-contact voltage sensors
Non-contact 3-phase 4-wire Clamp-on Power Logger, 90 V to 520 V at 50/60 Hz, 50 mA to 5 kA using external current sensors, harmonic measurement up to the 13th order, SD memory card slot (max. 8 GB), LAN and USB interface

€3,058.00*
20 %
LR5051
LR5051 - Data Logger for Current Clamps
The LR5051 pocket-sized logger records load and leakage currents across two channels, featuring high accuracy and compact design for easy deployment. Technical Details: Current range: 500 mA to 1000 A AC rms Accuracy: +/- 2%rdg, +/- 0.13%f.s. Memory: 60,000 data points, 2ch memory Recording intervals: Starting from 1s 

€270.40* €338.00*
20 %
LR8513
LR8513 - Bluetooth Current Logger
Compact 2-channel data logger, AC current logging with BNC current sensors, Bluetooth, max. 500 000 data points/channel, AC, DC or battery operation

€366.40* €458.00*