DM7276-03: Precision DC Voltmeter, 7½ digits, 9 ppm accuracy, LAN, USB, RS-232C
€2,738.00
Shipping costs : €9.90 (Standard)
In stock in Germany
- Fast delivery across Europe
- EU business invoices
€2,738.00
Product information DM7276-03: Precision DC Voltmeter, 7½ digits, 9 ppm accuracy, LAN, USB, RS-232C
Key Specifications
- 9 ppm accuracy, guaranteed for 1 year
- 7½ digits, down to 10 nV resolution
- Self-calibration for long-term tests
- Contact check for 2-wire measurement
- Temperature compensation with Z2001
Typical Applications
- OCV measurement in aging and self-discharge tests of lithium-ion cells
- External potential measurement on lithium-ion cells to detect insulation defects in the outer film
- Development of lithium-ion cells and electric double-layer capacitors
- Precision measurement of low sensor output voltages
| Model | Interfaces | Measurement accuracy, 1 year (± % rdg. ± offset) | ||||
|---|---|---|---|---|---|---|
| 100 mV | 1000 mV | 10 V | 100 V | 1000 V | ||
| DM7276-01 | LAN, USB, EXT I/O | ±0.0015 % ±2 µV |
±0.0011 % ±3 µV |
±0.0009 % ±12 µV |
±0.0020 % ±0.8 mV |
±0.0025 % ±2 mV |
| DM7276-02 | GP-IB, LAN, USB, EXT I/O | |||||
| DM7276-03 | RS-232C, LAN, USB, EXT I/O | |||||
| DM7275-01 | LAN, USB, EXT I/O | ±0.0030 % ±2 µV |
±0.0020 % ±3 µV |
±0.0020 % ±12 µV |
±0.0030 % ±0.8 mV |
±0.0035 % ±2 mV |
| DM7275-02 | GP-IB, LAN, USB, EXT I/O | |||||
| DM7275-03 | RS-232C, LAN, USB, EXT I/O | |||||
Detailed Product Overview
The HIOKI DM7276 is a 7½-digit precision DC voltmeter for measurements in which a few microvolts matter, such as aging and self-discharge tests on lithium-ion cells or the development of electric double-layer capacitors. In the 10 V range, its accuracy is ±0.0009 % rdg. ±12 µV, which corresponds to 48 µV on a 4 V lithium-ion cell.
Five ranges cover 100 mV to 1000 V, with a resolution of 10 nV in the lowest range. It comes in three versions that differ only in their interfaces. The DM7275 offers the same functions and interfaces with an accuracy of 20 ppm.
Self-calibration and low drift
In aging tests that run for days or weeks, the instrument itself must not drift. The DM7276 therefore compensates for fluctuations in its measurement circuitry with fully automatic selfcalibration. It runs between readings or while the instrument waits for a trigger, so it never interrupts a measurement and never has to be started manually. Its voltage reference is built from components that undergo long-term testing at HIOKI before assembly.
Changes in room temperature have little effect on the voltmeter itself. Between 18 °C and 28 °C, their influence is already covered by the accuracy specification. Beyond that band, down to 0 °C and up to 40 °C, just 5 % of the accuracy is added per degree, or 2.4 µV/°C on a 4 V cell. The cell responds to temperature many times more strongly. If a reading follows the room temperature, the change therefore comes mainly from the cell.
Noise and interference rejection
How much noise remains in a reading depends mainly on the integration time, the period over which the instrument averages the input signal. It is usually expressed in power line cycles. With an integration time of one cycle, or 20 ms at 50 Hz, noise adds only 0.0001 % of range ±0.5 µV to the measurement error.
Averaging over whole power line cycles largely cancels out interference at the mains frequency. At 10 power line cycles, the floating input suppresses this normal mode noise by at least 120 dB, and it rejects common mode interference by at least 140 dB at DC and 100 dB at AC. Input bias current is no more than 30 pA in the 100 mV and 1 V ranges and 50 pA in the 10 V range. Test leads are not included and are chosen to suit the application.
Temperature and contact
A temperature change of just 1 °C can shift the open circuit voltage of a lithium-ion cell by several tens of microvolts. Left uncorrected, this would mask voltage changes that the DM7276 is able to resolve. Using the optional Z2001 Temperature Sensor, the instrument therefore records the ambient temperature alongside the voltage and converts each reading to a reference temperature. The conversion relies on the temperature coefficient of the cell type, which the user determines beforehand. As the sensor measures ambient rather than cell temperature, both should be given time to settle before measuring.
External potential measurement finds insulation defects in the outer film of lithium-ion cells by measuring the voltage between an electrode and the outer casing. Here, as in aging tests, the reading decides whether a cell is kept or rejected. With poor probe contact, a good cell can be scrapped or a faulty one can slip through. With its contact check enabled, the DM7276 therefore verifies before every measurement that both probes are in contact. It measures the capacitance between the probes using a 10 mVrms signal that does not stress the cell, and only outputs a reading when contact is sufficient.
SW1001/SW1002 Multiplexer System
To monitor large numbers of cells over long periods, the DM7276 can be combined with HIOKI's SW1001/SW1002 multiplexer system. The voltmeter connects in a 2-wire configuration via the SW9001 Multiplexer Module. The SW1001 has three slots and the SW1002 twelve, giving up to 264 voltage channels with the SW1002. The contact check flags any channel where a probe has no contact.
A second instrument can share the same multiplexer system, either a battery tester from the BT356xA series or the BT4560 Battery Impedance Meter. The system switches between the two, so that the DM7276 measures open circuit voltage and the second instrument internal resistance on the same channels.
Three versions, same measurement performance
Every DM7276 comes with three interfaces as standard: LAN for network integration, USB for connection to a PC and a photocoupler-isolated EXT I/O for PLCs and test systems. Readings, screenshots and settings can also be saved straight to a USB flash drive. HIOKI's free PC application records measurement series over USB and exports them as CSV files. This is the configuration of the DM7276-01.
The DM7276-02 adds a factory-installed GP-IB interface to IEEE 488.2, intended for integrating the instrument into established test stations that run on a GP-IB bus. On the DM7276-03, the extra interface is RS-232C, for PLCs and other controllers that communicate serially. Accuracy, measurement functions and operation are identical across all three versions.
- DM7276 Precision DC Voltmeter
- Power Cord
- Instruction Manual
- Operating Precautions
Dimensions & Packaging
| Length | 88 mm |
|---|---|
| Width | 215 mm |
| Height | 232 mm |
| Weight | 2.3 kg |