CT7812 - AC/DC Current Probe

Ultra-small, zero-flux clamp-on AC/DC Current Probe using flux gate detection, high accuracy ±0.3 %, max. resolution 0.1 mA, wide temperature range -40 to 85 °C, measurable current up to 2 A, designed exclusively for LR8450 Series Data Logger

Product information "CT7812 - AC/DC Current Probe"

Banner Specs:  
  • High accuracy ±0.3 % 
  • Measurable current 100 µA to 2 A 
  • Ultra small size sensor with slide open/lock mechanism 
  • Wide temperature range -40 to 85 oC
  • DC to 5 kHz bandwidth with LR8450 Data Logger 

USPs:
  • Easy installation, even in tight spaces 
  • Accurate low current measurement 
  • Allows for stable measurement from Alaska to the Sahara 

Applications:
  • Development and analysis tool for improving the energy efficiency of electric vehicles (EV) 
  • Consumption monitoring of low power EV circuits like Engine Control Units (ECUs), interior lighting etc.
  • Optimizing the overall energy consumption of low power circuits in EVs to extend the driving range
  • Optimizing the overall energy consumption of low power circuits in electric construction vehicles or agricultural vehicles to extend the time between charging Product 

In detail: 
The ultra small CT7812 Current Probe with its slide-open/lock feature is one of the smallest high-accuracy sensors on the market. Contactless measurement of currents up to 2 A AC/DC are possible even in the most confined spaces with a basic accuracy of ±0.3 % and an impressive resolution of 0.1 mA (200 mA range). It gives development engineers of EVs, electric trucks, buses, construction, and agricultural vehicles the possibility to accurately monitor energy consumption even under the most extreme temperature conditions. 

Exclusively designed to be used with the LR8450 Data Logger Series, up to 55 currents can be logged simultaneously on one device at a bandwidth of up to 5 kHz. Applications range from providing a detailed energy consumption insight of a vehicle under test to other complex electrical systems. The CT7812 with its PL14 connector can be used with the LR8450 Data Logger either in combination with the U8556 Plug-in Current Module or alternatively with the LR8536 Wireless Current Module (requires LR8450-01).


More than specs – find more details here:
🔗 Measure, Analyze & Optimize Current Consumption
  • CT7812 
  • Colored labels (for channel identification) 
  • Carrying case 
  • Instruction Manual 
  • Operating Precautions

Related products

LR8450
LR8450 - Modular multi-channel Data Logger
Multi-channel data logger, connect up to 4 plug-in modules with up to 120 analog channels, max. 1 ms update interval, max. 100 VDC, 8 inputs for pulse/logic/rotational speed, 7“ TFT-Display, GigabitLAN und USB / SD card, optional battery operation

€1,818.00*
LR8450-01
LR8450-01 - Wireless modular multi-channel Data Logger
WLAN-fähiger Mehrkanal-Datenlogger mit bis zu 4 Einsteck- und 7 WLAN-Modulen (max. 330 Kanäle), 1 ms Intervall, 100 VDC, 8 Eingänge für Puls/Logik/Drehzahl, 7″ TFT, Gigabit-LAN, USB/SD, optionaler Batteriebetrieb.

€2,158.00*
U8556
U8556 - 5-channel logger module for current sensors, 1 ms
5-channel plug-in interface and signal conditioning module for the LR8450 Series Data Logger to connect HIOKI Current Sensors with a PL14 connector

€1,318.00*
LR8536
LR8536 - 5-channel wireless logger module for current sensors, 1 ms
5-channel wireless interface and signal conditioning module for the LR8450-01 Data Logger to connect HIOKI Current Sensors with a PL14 connector

€1,858.00*
CT7822
CT7822 - AC/DC Current Probe
Ultra-small, zero-flux clamp-on AC/DC Current Probe using flux gate detection, high accuracy ±0.3%, max. resolution 1 mA, wide temperature range -40 to 85 oC, measurable current up to 20 A, designed exclusively for LR8450 Series Data Logger

€1,268.00*
L0220-01
L0220-01 - Extension cable
The L0220-01 extention cable is made for extending a sensor cable connected to Hioki Display Units equipped with HIOKI connector PL14. Technical details: Length: 2m Use for: CT7631, CT7636, CT7642, CT7731, CT7736, CT7742, CM7290, CM7291 Connector type: Hioki PL14

€198.00*
L0220-02
L0220-02 - Extension cable
The L0220-02 extention cable is made for extending a sensor cable connected to Hioki Display Units equipped with HIOKI connector PL14. Technical details:Length: 5m Use for: CT7631, CT7636, CT7642, CT7731, CT7736, CT7742, CM7290, CM7291 Connector type: Hioki PL14

€288.00*
L0220-03
L0220-03 - Extension cable
The L0220-03 extention cable is made for extending a sensor cable connected to Hioki Display Units equipped with HIOKI connector PL14. Technical details: Length: 10m Use for: CT7631, CT7636, CT7642, CT7731, CT7736, CT7742, CM7290, CM7291 Connector type: Hioki PL14

€318.00*