Z5021 - Power supply unit for current or differential probes, factory option for MR6000

Power supply unit for up to 8 current clamps of the CT670x/327x Series, up to 4 current clamps of the CT671x Series, up to eight 9322 or up to three P9000 differential probes, factory option for MR6000, 12 VDC and 0.6 A per terminal
Product information "Z5021 - Power supply unit for current or differential probes, factory option for MR6000"
The Z5021 Probe Power Unit for the MR6000 Memory Recorder is a factory-installed option designed to provide power to up to eight current probes or clamps from the CT670x or 327x Series. Additionally, the Z5021 supports up to four CT6710 or CT6711 current clamps. For applications requiring higher voltages the Z5021 can power up to eight 9322 or up to three P9000 Differential Probes. 

It delivers a stable output voltage of ±12 V DC and a rated output current of 0.6 A per terminal. 

The Z5021 must be ordered together with the main instrument at the time of purchase. For an installation at a later stage, the main instrument needs to be sent to a HIOKI service center.
  • Z5021 Stromversorgung

Related products

MR6000
MR6000 - 32-channel modular memory recorder, 200 MS/s, 1000V, touchscreen
Modular memory recorder, up to 32 channels, max. sampling rate 200 MS/s, max 1000 VDC isolated direct voltage input, up to 256 GB storage with SSD option, intuitive user interface, touchscreen, real-time waveform calculation and real-time saving
CT6700
CT6700 - AC/DC Current Probe, 5 A / 50 MHz
Hall sensor based zero-flux current probe suitable for capturing very small to high-speed currents

€2,838.00*
CT6701
CT6701 - AC/DC Current Probe, 5 A / 120 MHz
Hall sensor based zero-flux current probe suitable for capturing very small to high-speed currents

€3,398.00*
CT6710
CT6710 - AC/DC multi-range current probe, 30 A / 50 MHz
Hall sensor-based zero-flux current clamp, for detecting very small to very fast currents

€4,528.00*
CT6711
CT6711 - AC/DC multi-range Current Probe, 30 A / 120 MHz
Hall sensor based zero-flux current probe suitable for capturing micro to high-speed currents

€5,328.00*
3273-50
3273-50 - AC/DC Current Probe, 30 A / 50 MHz
Hall sensor based zero-flux current probe suitable for capturing small to high-speed currents

€2,608.00*
3274
3274 - AC/DC Current Probe, 150 A / 10 MHz
Hall sensor based zero-flux current probe suitable for capturing small to high-speed currents

€3,178.00*
3275
3275 - AC/ DC Current Probe, 500 A / 2 MHz
Hall sensor based zero-flux current probe suitable for capturing small to high-speed currents

€3,858.00*
3276
3276 - AC/DC Current Probe, 30 A / 100 MHz
Hall sensor based zero-flux current probe suitable for capturing small to high-speed currents

€3,398.00*
9322
9322 - Differential probe
The Hioki 9322 Differential Probe is a versatile 3-in-1 probe designed for the floating measurement of high-voltage waveforms, detecting power line surge noise, and providing true RMS rectified output of high-voltage AC. With the ability to handle up to 2000 V DC and 1000 V AC (CAT II), the 9322 ensures safe and accurate measurements even in demanding environments. This probe is compatible with the Memory Memory recorder series and can be powered via an AC adapter or Hioki’s Probe Power Unit Z5021. It offers a wide frequency range for detecting high-frequency components, making it ideal for inverter circuits and power supply noise detection. Technical details: Measurement functions: o DC mode: Waveform monitor output, DC to 10 MHz ±3 dB o AC mode: Detection of power line surge noise, 1 kHz to 10 MHz ±3 dB o RMS mode: Rectified RMS output of DC and AC voltages, DC, 40 Hz to 100 kHz o Response speed: 200 ms or less (400 V AC) Max. allowable input: 2000 V DC, 1000 V AC Max. rated voltage to earth: o 1000 V AC/DC (CAT II) when using the Grabber Clip L9243 o 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III) when using alligator clips Output: Voltage division ratio 1/1000, BNC terminal (3-mode selectable: DC/AC/RMS) • DC amplitude accuracy: ±1% f.s. (1000 V DC or less), ±3% f.s. (2000 V DC) RMS amplitude accuracy: ±1% f.s. (DC, 40 Hz to 1 kHz), ±4% f.s. (1 kHz to 100 kHz)Input resistance and capacity: o H-L: 9 MΩ, approx. 10 pF (at 100 kHz) o H-case, L-case: 4.5 MΩ, approx. 20 pF (at 100 kHz) Power supply: o General requirement: +5 V to +12 V, less than 300 mA (DC jack OD 5.5 mm, ID 2.1mm)Hioki provided power supplies: o AC Adapter 9418-15 o Z5021combined plus Power Cord 9248 o Use of Logic terminal on Memory Recorder plus Power Cord 9324 o Use of sensor terminal of F/V Unit 8940 plus Power Cord 9325 o Use of DC power output terminal attached to the input unit for the 8855 through Power Cord 9328 o Via the 8860 series Probe Power Unit 9687 plus Power Cord 9248 Dimensions and mass: 70 mm (W) × 150 mm (H) × 25 mm (D), 350 g, Cord length: Input 46 cm, Output 1.3 m

€738.00*
P9000-01
P9000-01 - Differential probe
The Differential Probe P9000-01 is designed to offer superior flexibility for waveform monitoring in high-voltage environments. Ideal for use with Hioki Memory Reorders and Dataloggers, it allows accurate and reliable measurement in various industrial applications, such as electric vehicles, solar power systems, and commercial power circuits. Compact and lightweight, this probe offers 1000 V AC/DC measurements with a choice between 1000:1 and 100:1 division ratios. With a robust operating temperature range, it ensures performance even in challenging conditions. Technical Specifications: Measurement Functions: Waveform monitor output only Frequency Characteristics (Wave Mode): DC to 100 kHz, -3 dB Division Ratio: 1000:1 or 100:1 (user selectable) DC Amplitude Accuracy: ±0.5% f.s. Input Resistance and Capacity: 10.5 MΩ, 5 pF or less (at 100 kHz) Maximum Allowable Input: 1000 V AC/DCMax. Rated Voltage to Earth: 1000 V AC/DC (CAT III) Operating Temperature Range: -40°C to 80°CPower Supply Options: o AC Adapter (Z1008), USB, External DC (2.7V to 15V DC)Dimensions: 128 mm (W) × 36 mm (H) × 22 mm (D) Mass: 170 g Cord Length: Input 70 cm; Output 1.5 m

€478.00*
P9000-02
P9000-02 - Differential probe
The Differential Probe P9000-02 combines waveform monitoring with AC RMS value output, offering increased versatility for high-voltage applications. With the capability to monitor waveforms and RMS values, it is suitable for industrial applications such as electric vehicle battery circuits, solar power systems, and commercial high-voltage circuits. The probe is lightweight, compact, and offers high accuracy across a wide range of operating temperatures, ensuring durability and performance in demanding conditions. Technical Specifications: Measurement Functions: Waveform monitor output and AC RMS value output (switchable) Frequency Characteristics (Wave Mode): DC to 100 kHz, -3 dB Frequency Characteristics (RMS Mode): 30 Hz to 10 kHz RMS Amplitude Accuracy: ±1% f.s. (30 Hz to 1 kHz); ±3% f.s. (1 kHz to 10 kHz) Response Time (RMS Mode): 300 ms (rising), 500 ms (falling) Division Ratio: 1000:1 or 100:1 (user selectable) DC Amplitude Accuracy: ±0.5% f.s. Input Resistance and Capacity: 10.5 MΩ, 5 pF or less (at 100 kHz) Maximum Allowable Input: 1000 V AC/DC Max. Rated Voltage to Earth: 1000 V AC/DC (CAT III) Operating Temperature Range: -40°C to 80°C Power Supply Options: o AC Adapter (Z1008), USB, External DC (2.7V to 15V DC) Dimensions: 128 mm (W) × 36 mm (H) × 22 mm (D) Mass: 170 g Cord Length: Input 70 cm; Output 1.5 m

€608.00*