9729 - Compact Flash Card 1 GB

Product information "9729 - Compact Flash Card 1 GB"
The PC CARD 9729 is a removable compact flash card designed for storing critical measurement data and seamlessly transferring it to a PC. It meets industrial standards, ensuring reliable performance in demanding environments. 

Technical Specifications 
  • Memory Capacity: 1GB 
  • Applicable Standards: PCMCIA compliant
  • 9729 
  • Notes on using the PC card

Related products

LR8431-20
LR8431 - Handheld 10-channel Data Logger for voltage, temperature and pulse logging
Banner Specs 10 isolated analog & 4 pulse channels 10 ms update interval 5 voltage ranges, 100 mV to 60 VDC (direct input) Smallest voltage resolution: 5 µV - 16-bit resolution Applications Long-term autonomous logging of voltages Temperature monitoring with thermocouples Smallest voltage rangeDirect input for heatflow sensorsLR8431100 mV-LR843210 mVjaIn detail:The HIOKI LR8431 Data Logger is a compact, high-performance data logger designed for precise and efficient multi-channel data collection. It features 10 isolated analog and 4 pulse channels, allowing for comprehensive monitoring across various parameters. The device supports real-time data recording at an impressive 10 ms update interval, making it ideal for capturing fast-changing signals. With a smallest voltage resolution of 5 µV and the capability to handle direct voltage inputs in 5 ranges from 100 mV to 60 VDC, it offers versatility for a wide range of industrial applications. The logger can be powered in multiple ways, offering flexibility and convenience for users in different settings. It comes with an included AC adapter that supports voltages from 100 to 240 V AC. Additionally, the logger can be powered by an optional battery pack for portable use, providing up to 2.5 hours of continuous operation. For longer use in field applications or in vehicles, the LR8431 also accepts a wide range DC power input from 10 to 16 V DC, ensuring reliable operation in various scenarios. Analog voltage signals as well as various types of thermocouples are connected to the logger's input via M3 screw terminals. Equipped with a 16-bit delta-sigma A/D converter and proprietary digital filtering technology, the LR8431 effectively reduces noise, including inverter switching noise and line-frequency hum. This ensures that measurements remain accurate and reliable, even in electrically noisy environments. The LR8431 offers multiple storage options up to 16 GB of capacity, ensuring that users can log large amounts of data without interruption. Additionally, the integrated software facilitates seamless data analysis, enhancing the overall user experience. Its portability and robust features make the Data Logger LR8431 a valuable tool for professionals in fields like automotive testing, electronics, and HVAC system evaluation.

€1,358.00*
LR8432-20
LR8432 - Handheld 10-channel Data Logger with native support for heat flow sensors
10-channel handheld data logger for voltage / temperature plus 4 channels for pulse / rotation, direct input of heat flow sensors, isolated inputs, up to 60 VDC, max. update interval 10 ms, up to 16 GB USB storage capacity, LCD display, signal input via M3 screw terminals, optional battery pack Banner Specs: 10 isolated analog & 4 pulse channels Direct input of heat flow sensors 6 voltage ranges, 10 mV to 60 VDC (direct input) Smallest voltage resolution of 500 nV 10 ms update interval Applications: Logging of heat flow in processes and R&D Long-term autonomous logging of voltages Temperature monitoring with thermocouples          Smallest voltage range            Direct input for heatflow sensorsLR8431100 mV-LR843210 mVyesIn detail: The HIOKI LR8432 Heat Flow Data Logger is a variant of the popular LR8431 data logger. In addition to the functions and specifications of the LR8431, the LR8432 offers direct input for heat flow sensors, eliminating the need for manual conversion of the sensors' measured voltage values. Furthermore, the LR8432 features 6 voltage ranges instead of 5, with the additional 10 mV range enabling a smallest voltage resolution of 500 nV.The LR8432 is a compact, high-performance device designed for precise and efficient multichannel data collection. It features 10 isolated analog and 4 pulse channels, enabling comprehensive monitoring across various parameters. Supporting real-time data recording with an impressive 10 ms update interval, it is ideal for capturing fast-changing signals. With a smallest voltage resolution of 500 nV and 6 voltage ranges from 10 mV to 60 VDC, the LR8432 adapts to diverse industrial applications. The logger can be powered in multiple ways, offering flexibility and convenience for users in different settings. It comes with an included AC adapter that supports voltages from 100 to 240 V AC. Additionally, the logger can be powered by an optional battery pack for portable use, providing up to 2.5 hours of continuous operation. For longer use in field applications or in vehicles, the LR8432 also accepts a wide range DC power input from 10 to 16 V DC, ensuring reliable operation in various scenarios. Analog voltage signals as well as various types of thermocouples are connected to the logger's input via M3 screw terminals. Additionally, heat flow sensors can be directly connected, with their sensitivity configurable in the logger's settings, to provide direct output of the measured heat flow value in W/m². Equipped with a 16-bit delta-sigma A/D converter and proprietary digital filtering technology, the LR8432 effectively reduces noise, including inverter switching noise and line-frequency hum. This ensures that measurements remain accurate and reliable, even in electrically noisy environments. The LR8432 offers multiple storage options up to 16 GB of capacity, ensuring that users can log large amounts of data without interruption. Additionally, the integrated software facilitates seamless data analysis, enhancing the overall user experience. Its portability and robust features make the Data Logger LR8432 a valuable tool for professionals in fields like automotive testing, electronics, and HVAC system evaluation.

€1,658.00*
MR8870-20
MR8870-20 - Portable data recorder
The Hioki MR8870-20 Data Recorder is a versatile, compact oscilloscope-like device designed for high-speed waveform recording and long-term RMS data capture. It features isolated inputs for safe measurement of power lines, and its real-time data-saving functionality ensures continuous monitoring with minimal interruptions.With up to 1 MS/s sampling rate and the ability to record fluctuations in RMS data, the MR8870-20 is ideal for applications such as motor startup analysis, inverter output waveform monitoring, and CB timing measurements. Its portable design makes it easy to use on-site. Technical Details: Channels: 2 analog, 4 logic channels Max Sampling Rate: 1 MS/s (1 µs) Memory Capacity: 12 bits × 2 M-Words/channel Storage: CF card (up to 2 GB, FAT/FAT32) Display: 4.3-inch TFT color LCD Operating Temperature: 0°C to 40°C Power Supply: AC adapter (100–240 V), Battery Pack 9780 Dimensions: 176 mm (W) × 101 mm (H) × 41 mm (D) Weight: 600 g (with battery pack)

€1,248.00*
MR8880-20
MR8880 - Portable Memory Recorder, 4 Channels
The MR8880 is a 4 channel portable data acquisition system (DAQ) with a maximum sampling rate of 1Msamples/s on all analog channels simultaneously. It has 4 analog direct input channels for voltages up to 600V and 8 logic channels.Technical Details:   Complies CAT III 600V isolation for direct measure of 480V power line 4 complete isolated channels Operating temperature range of -10°C to 50°C Built to withstand mechanical shocks and vibrations PRESET function A memory capacity of 14bit × 1 M words/ch (1 word = 2 bytes)

€3,118.00*
PW3390
PW3390 - Portable 4-channel Power Analyzer
Portable 4-channel Power Analyzer, ±0.09% basic accuracy, DC to 200 kHz measurement band for power, 16-bit conversion, phase shift correction for HIOKI current sensors, 50 ms data update rate, 16-ch waveform/analog output, motor analysis function, WLTP compliant Banner Specs: ±0.09% basic power accuracy 4 power channels 200 kHz measurement band for power50 ms data update rate 1500 V max. input voltage USPs: - Approved for WLTP testing - Small and lightweight 4-channel power analyzer with motor analysis Applications:  WLTP testing Inverter efficiency measurements Motor efficiency measurements Solar power converter efficiency measurements  Model D/A Output Motor Analysis PW3390-01 ☐ ☐ PW3390-02 ☒ ☐ PW3390-03 ☒ ☒ In detail:The HIOKI PW3390 Power Analyzer is a compact, lightweight, 4-channel high-precision instrument designed to meet the demands of power and efficiency analysis across industries. Equipped with advanced features, this analyzer excels in measuring and analyzing electrical power and energy, making it an ideal solution for development, production, and field testing.Built for precision, the PW3390 delivers highly accurate power measurements with a basic accuracy of ±0.09%, ensuring reliable data for various applications. Its 4 power channels enable simultaneous multi-system evaluations with a frequency measurement band of up to 200 kHz for power.The instrument's harmonic analysis capabilities, featuring a data refresh time of 50 ms, allow users to study transient states and evaluate noise or harmonic interference up to 100 kHz.With motor analysis functionality, the PW3390 is perfect for motor and inverter efficiency evaluations. It provides measurements for torque, rotation speed, slip, and mechanical power, enabling comprehensive performance analysis of industrial drives. Multiple PW3390 units can be connected to operate as a coordinated measurement system with up to 32 channels. One unit serves as the primary controller, synchronizing the timing across all devices to ensure simultaneous data acquisition. For long-term monitoring, the PW3390 can be equipped with the D/A output function, offering a 16-channel analog output. The first 8 channels can be configured to output waveforms of all voltage and current inputs at an update rate of 500 kS/s. The remaining 8 channels can be assigned to numeric measurement values of basic parameters like U1, I2, and P4, with an update rate of 20 S/s. The PW3390 is ideally suited for use in the automotive sector, particularly for efficiency analyses of inverters in hybrid and electric vehicles, as well as for standardized testing procedures to determine energy consumption like WLTP (Worldwide Harmonized Light Vehicles Test Procedure). It also excels in renewable energy and power conversion applications, providing precise input and output power data for power conditioners.Designed with a user-friendly interface and a rugged build, the HIOKI PW3390 ensures intuitive operation and durability in industrial settings. Whether analyzing WLTP efficiency for (H)EVs, transient power, harmonics, or inverter and motor efficiency, the HIOKI PW3390 delivers outstanding performance and accuracy