M1100 - AC Power Supply Module for M7103 Power Module

Product information "M1100 - AC Power Supply Module for M7103 Power Module"
Dedicated AC Power Supply Module for M7103 Power Module, powers up to four M7103 modules, 100 V to 240 V. 

Banner Specs (= Attributes): 
  • For max. 4x M7103 modules 
  • 100 V to 240 V, 50/60 Hz 
In detail:
The M1100 is an AC power supply module specifically designed to provide power to up to four M7103 Power Modules. It can be connected to AC voltage from 100 V to 240 V at 50/60 Hz.
  • M1100 AC Power Supply Module

Related products

LR8101
LR8101 - Modular multi-channel Data Logger for system integration
Banner Specs:Max. 10 voltage/temperature modules and up to 300 channels (using M7100 and M7102) Max. 4 power modules and up to 12 power channels (using M7103) Max. update interval 5 ms High voltage logging up to 2000 VDC and current logging with HIOKI current sensors – rating 2 A to 2000 A Data transfer via TCP (LAN) Integrated alarms, trigger in/out and pulse/logic in USPs: Logging of temperatures and voltages, 1500 VDC / CAT II isolation to earth with M7100 High-accuracy power logging with M7103 High voltage logging (2000 VDC, 1000 VAC) with M7103 Wide variety of HIOKI current sensors for a reliable high-precision current logging Applications: Charge/discharge testing during cell formation and ageing Charge/discharge testing during development of battery modules and battery packs Development and optimization of Battery Management Systems (BMS) Development and optimization of Thermal Management Systems of batteries Quality inspection of PV string inverters during productionIn detail: The versatile, modular data logger LR8101 can be used in combination with a variety of modules. It is therefore the perfect solution for integration in applications requiring multiple channels and recording intervals as short as 5 ms. The logger can be installed in a 19” rack with an optional rack-mount kit. The LR8101 can be controlled via Gennect One or the freeof-charge Logger Utility software. Additionally, the logger provides several inputs and outputs for alarms, triggers and pulse signals. The enhanced noise resistance ensures accurate and reliable measurements. All available modules can be combined in one system setup, with the main two measurement objectives being power logging and voltage/temperature logging.Voltage & Temperature logging with the LR8101 The LR8101 Data Logger can be combined with up to ten M7100 or M7102 modules. The system provides utmost flexibility as it offers the possibility to choose the type and number of modules to exactly fit the test requirements. In combination with the module M7100 the logger can capture up to 150 channels at 5 ms update interval. With an isolation to Earth of 1500 VDC, CAT II measurements of voltages and temperatures of 800 V and even 1200 V batteries can be performed safely. When combined with module M7102 the logger offers up to 300 channels at 10 ms update interval. With an isolation of 600 VDC, CAT II it is the perfect solution for data logging of 400 V batteries. Besides voltage, both modules offer the possibility to capture temperature signals using thermocouples. Power logging with the LR8101 When adding the M1100 AC power supply module, up to four M7103 Power Measurement Modules can be connected offering a total of 12 channels for long-term high-precision logging of power. Alternatively, the M7103 can be used to measure voltages and currents. The voltage input channels offer direct measurement of voltages of up to 2000 VDC, 1000 VAC. Long-term current logging is possible with any of the high-precision HIOKI current sensors with an ME15W connector. The sensors are powered by the logger and do not require an external power supply.

€2,058.00*
LR8102
LR8102 - Modular multi-channel Data Logger for system integration, optical sync, UDP, CAN
Main unit for system integration applications, modular system, max. 3000 voltage/temperature channels or 120 power channels, for high voltage/high current applications, real-time data transfer via UDP, max. update interval 5 ms, for 19” rack systems Banner Specs:Max. 10 voltage/temperature modules per logger and up to 3000 channels with system synchronization (using M7100 and M7102) Max. 4 power modules per logger and up to 120 power channels with system synchronization (using M7103) Max. update interval 5 ms High voltage logging up to 2000 VDC and current logging with HIOKI current sensors– rating 2 A to 2000 A Real-time data transfer UDP (LAN) Integrated CAN data output, alarms, trigger in/out and pulse/logic inputs USPs:Synchronization of up to 10x LR8102 data loggers possible (max. 3000 ch.) Fast sampling & data transfer rate facilitates the use in Hardware-In-the-Loop (HIL) systems High-accuracy power logging with M7103 High voltage (2000 VDC, 1000 VAC) logging with M7103 Wide variety of HIOKI current sensors for a reliable high-precision current loggingApplications:Charge/discharge testing during cell formation and ageing Charge/discharge testing during development of battery modules and battery packsDevelopment and optimization of Battery Management Systems (BMS) Development and optimization of Thermal Management Systems of batteries Voltage and temperature monitoring in Hardware-In-the-Loop SimulationsQuality inspection of PV string inverters during production In detail:The versatile, modular data logger LR8102 can be used in combination with a variety of modules. It is therefore the perfect solution for integration in applications requiring multiple channels and recording intervals as short as 5 ms. The logger can be installed in a 19” rack with an optional rack-mount kit. The LR8102 can be controlled via Gennect One or the freeof-charge Logger Utility software. Alternatively, the logger offers the possibility for ultra-fast data transfer via UDP, which makes it the ideal solution for integration with charge/discharge testers and for real-time simulations such as HIL (Hardware-In-the-Loop). Additionally, the logger provides CAN data output as well as several inputs and outputs for alarms, triggers and pulse signals. The enhanced noise resistance ensures accurate and reliable measurements. All available modules can be combined in one system setup, with the main two measurement objectives being power logging and voltage/temperature logging. Voltage & Temperature logging with the LR8102The LR8102 data logger can be combined with up to ten M7100 or M7102 modules. The system provides utmost flexibility as it offers the possibility to choose the type and number of modules to exactly fit the test requirements. The LR8102 Data Logger can be further expanded by synchronizing up to ten data loggers using an optical link, which allows to measure up to 3000 voltage / temperature channels. In combination with the module M7100 the logger can capture up to 150 channels at 5 ms update interval. With an isolation to Earth of 1500 VDC, CAT II measurements of voltages and temperatures of 800 V and even 1200 V batteries can be performed safely. When combined with module M7102 the logger offers up to 300 channels at 10 ms update interval. With an isolation of 600 VDC, CAT II it is the perfect solution for data logging of 400 V batteries. Besides voltage, both modules offer the possibility to capture temperature signals using thermocouples. Power logging with the LR8102 When adding the M1100 AC power supply module, up to four M7103 Power Measurement Modules can be connected offering a total of 12 channels for long-term high-precision logging of power. This set up can be further expanded with the synchronization of up to ten data loggers to achieve a total of 120 power channels. Alternatively, the M7103 can be used to measure voltages and currents. The voltage input channels offer direct measurement of voltages of up to 2000 VDC, 1000 VAC. Long-term current logging is possible with any of the high-precision HIOKI current sensors with an ME15W connector. The sensors are powered by the logger and do not require an external power supply.