LR8450 - Modular multi-channel Data Logger LR8450

Product information "LR8450 - Modular multi-channel Data Logger LR8450"
Multi-channel data logger, connect up to 4 plug-in modules with up to 120 analog channels, max. 1 ms update interval, max. 100 VDC, 8 inputs for pulse/logic/rotational speed, 7“ TFT-Display, GigabitLAN und USB / SD card, optional battery operation 

Banner Specs 
  • Up to 120 analog channels with plug-in modules and 8 pulse/logic inputs 
  • Voltage, current, temperature, humidity, resistance, heat flow, strain, pulse, CAN and CAN FD (input and output) 
  • Max. 1 ms update interval 
  • Optional battery operation 
  • Max. 100 VDC direct input and 300 V AC/DC, CAT II isolation to earth 

USPs 
  • High-speed data recording with up to 1 ms 
  • High-precision current logging of up to 20 channels with dedicated HIOKI current sensors 
  • CAN and CAN FD data input and output and measurement of strain, stress and heat flow 

Applications 
  • Current consumption in Electric Vehicles (EVs) 
  • Logging of voltage, current, temperature, resistance, vibration and strain during product development and production 
  • Long-term observation of stray currents in metro railway stations 
  • Observation of voltage, temperature and temperature distribution in Light Duty, Heavy Duty, construction and agricultural machinery (and data output via CAN) 
  • Process observation with heat flow sensors 
  • Measurement of temperature and heat flow for quality control, e.g. food processing 
  • Thermal Runaway of EV batteries 
  • Monitoring and maintenance of industrial equipment 
  • Observation of temperature and humidity for environmental and climate studies 

In detail:
The modular LR8450 Data Logger is a highly versatile and adaptable solution, built for professionals who require both speed and scalability. This high-speed, multi-channel logger supports up to 120 channels by utilizing four plug-in modules, with seven different module types available to capture data such as voltage, current, temperature (thermocouples or Pt100/1000), humidity, resistance, strain, pulse, and CAN (FD). HIOKI current sensors enable high-precision AC/DC current logging from 2 A to 6000 A, supporting up to 20 directly connected sensors. Its 1 ms recording interval is ideal for capturing fast-changing signals, while its 7" TFT display provides clear, real-time data visualization for easy on-site monitoring. 

The LR8450 features a 16-bit analog-to-digital converter (ADC) for enhanced measurement precision, and all modules that can be connected to the LR8450 are capable of handling direct voltages up to 100 V, with an isolation to earth of 300 V DC/AC, CAT II. 

With the flexibility to run for hours on battery power, the LR8450 ensures continuous logging for both stationary and mobile testing. Data can be stored on SD cards or USB sticks, and retrieval is made easy through its Gigabit LAN connector. The logger also features a DC input for additional supply power flexibility, making it an essential tool for demanding vehicle and industrial testing applications. Whether monitoring electric vehicles or managing complex industrial systems, the LR8450 sets the standard for precision and adaptability in data logging.
  • LR8450 Data Logger
  • Quick Start Guide 
  • LOGGER Application Disc ( contains: Quick Start Guide, User Guide, Logger Utility, Logger Utility User Guide, CAN Editor, CAN Editor User Guide, Communication User Guide
  • USB-Cable 
  • AC-Adapter Z1014

Modules

U8550
U8550 - Logger Module for Voltage and Temperature, 10 ms, 15 Channels
The U8550 is a plug-in module for the Memory Logger LR8450 und LR8450-01 with 15 channels that supports voltage and temperature (thermocouples) measurement, as well as humidity sensing. It offers a maximum sampling rate of 10 ms. Key Features: > 15 channels for voltage, temperature (thermocouples), and humidity measurement. > Maximum sampling rate of 10 ms. > Suitable for voltage and temperature data logging. > M3 screw-type terminal block for connections.

€658.00*
U8551
U8551 - Universal Logger Module, 10 ms, 15 Channels
The U8551 is a plug-in module for the LR8450 and LR8450-01 memory loggers. This unit has 15 channels and can measure voltage, temperature (thermocouples and RTD), humidity, and resistance. It supports a maximum sampling rate of 10 ms and uses a push-button type terminal block (4 terminals per channel). Key Features: > 15 channels for voltage, temperature (thermocouples, RTD), humidity, and resistance measurement. > Maximum sampling rate of 10 ms. > Push-button type terminal block for ease of use. > All channels are isolated, ensuring versatile measurement.

€988.00*
U8552
U8552 - Logger Module for Voltage and Temperature, 30 Channels
The U8552 plug-in module for the Memory Logger LR8450 und LR8450-01 is similar to the U8550 but with 30 channels. This unit can measure voltage, temperature, and humidity. Its sampling rate is up to 20 ms, but when 15 or fewer channels are used, it supports 10 ms. Key Features: > 30 channels for voltage, temperature (thermocouples), and humidity measurement. > Maximum sampling rate of 20 ms (or 10 ms with 15 or fewer channels). > Push-button type terminal block for easy connectivity. > Ideal for high-channel measurements in larger setups. 

€988.00*
U8553
U8553 - Voltage Logger Module, 1 ms, 5 Channels
The U8553 plug-in module for the Memory Logger LR8450 und LR8450-01 has 5 channels dedicated to high-speed voltage measurement, with a smallest sampling interval 1 ms. It is ideal for capturing fast voltage changes. Key Features: > 5 high-speed channels for voltage measurement. > Maximum sampling rate of 1 ms for rapid data acquisition. > M3 screw-type terminal block for secure connections. > Suited for applications requiring high-speed voltage monitoring.

€988.00*
U8554
U8554 - Logger Module for Strain Gauges
The U8554 plug-in module for the LR8450 and LR8450-01 memory loggers is a specialised unit with 5 channels for measuring deformation under pressure. It can be connected directly to strain gauges and supports various configurations such as the 1-gauge or 4-gauge method. The maximum sampling rate is 1 ms, which makes it suitable for applications with precise strain measurement.Important functions:5 channels for measuring strains with different strain gauge configurations.. Maximum sampling rate of 1 ms.Push-button terminal block for easy connection of strain gaugesUnterstützt 1-Messstreifen-, 2-Messstreifen- und 4-Messstreifen-Methoden, wodurch sie für verschiedene Dehnungsanwendungen anpassbar ist.

€2,088.00*
U8555
U8555 - Logger Module for CAN/CAN FD input and output
CAN unit, CAN/CAN FD input and output switchable, 2ch, Max. 10ms/S (up to 50 CAN signals), Max. 500 CAN signals (at 100 ms/S), for LR8450 and LR8450-01

€2,088.00*
U8556
U8556 - Logger Module for Current Sensors
Logger module for current sensors with PL14 connector, 5 channels, sampling interval 1ms, for LR8450 and LR8450-01

€1,278.00*

Related products

L1012
L1012 - Supply cable for Hioki SP7001, SP7002, LR8101 and LR8102
Power cable, for SP7001, SP7002, LR810X

€38.00*
Z1014
Z1014-AC Adapter
AC Adapter, 100 V to 240 V AC, for the KR8450 series

€148.00*
Z1007
Z1007 - Battery Pack, Li-Ion
The Z1007 is a Li-ion battery pack designed for the LR8410 series, capable of charging while installed for continuous operation. Technical Details: • Battery type: Li-ion • Compatibility: LR8410, LR8416, LR8510, LR8511

€158.00*
CT7812
CT7812 - AC/DC CURRENT PROBE
The CT7812 is a high-precision AC/DC current sensor optimized for automotive and power electronics applications. It is specifically designed for high-sensitivity measurements, with the ability to detect low-level currents in tight wiring environments. Technical Details: Current Rating: 2 A (AC/DC) Frequency Range: DC to 100 kHz Accuracy: ±0.3% rdg, ±0.1% f.s. Operating Temperature: -40°C to 85°C Input Impedance Requirement: 1 MΩ or higher

€1,228.00*
CT7822
CT7822 - AC/DC CURRENT PROBE
"The CT7822 is an AC/DC current sensor designed for precision measurements of higher current ranges. Its compact design allows it to fit into tight spaces, while its wide operating temperature range makes it suitable for harsh environments. Technical Details: • Current Rating: 20 A (AC/DC) • Frequency Range: DC to 100 kHz • Accuracy: ±0.3% rdg, ±0.1% f.s. • Operating Temperature: -40°C to 85°C • Input Impedance Requirement: 1 MΩ or higher "

€1,228.00*
C1012
C1012 - CARRYING CASE
Carrying case, with compartment for accessories, for the LR8450 series

€388.00*

Model variant

LR8450-01
LR8450-01 - Wireless modular multi-channel Data Logger LR8450-01
Wireless multi-channel data logger, connect up to 4 plug-in and 7 wireless modules for max. 330 analog channels, max. 1 ms update interval, max. 100 VDC, 8 inputs for pulse/logic/rotational speed, 7“ TFT-Display, Gigabit-LAN und USB / SD card, optional battery operation Banner Specs Wireless LAN capability Up to 330 analog channels with plug-in and wireless modules and 8 pulse/logic inputs Voltage, current, temperature, humidity, resistance, heat flow, strain, pulse, CAN and CAN FD input and output Max. 1 ms update interval Optional battery operation USPs Maximum flexibility and high accuracy with wireless modules and real-time data transfer via Wireless LAN High-speed data recording with up to 1 ms Up to 330 analog channels and up to 55 current channels High-precision current logging with dedicated HIOKI current sensors CAN and CAN FD data input and output and measurement of strain, stress and heat flow Applications Current consumption in Electric Vehicles (EVs) Logging of voltage, current, temperature, resistance, vibration and strain during product development and production Long-term observation of stray currents in metro railway stations Observation of voltage, temperature and temperature distribution in Light Duty, Heavy Duty, construction and agricultural machinery (and data output via CAN) Process observation with heat flow sensors Measurement of temperature and heat flow for quality control, e.g. food processing Thermal Runaway of EV batteries Monitoring and maintenance of industrial equipment Observation of temperature and humidity for environmental and climate studies In detail:The modular LR8450-01 Data Logger is a highly versatile and adaptable solution, built for professionals who require both speed and scalability. This high-speed, multi-channel logger supports up to 120 channels through four plug-in modules, and with the addition of seven wireless modules, the maximum number of channels expands to 330. These wireless modules can be positioned in confined spaces or near the device under test, significantly reducing efforts and enhancing the measurement accuracy. The recorded data is transmitted via wireless LAN to the logger and can be monitored in real-time. The LR8450-01 features a 16-bit analog-to-digital converter (ADC) for enhanced measurement precision, and all modules that can be connected to the LR8450-01 are capable of handling direct voltages up to 100 V, with an isolation to earth of 300 V DC/AC, CAT II. Seven different module types are available for capturing data such as voltage, current, temperature (thermocouples or Pt100/1000), humidity, resistance, strain, pulse, and CAN (FD). HIOKI current sensors enable high-precision AC/DC current logging from 2 A to 6000 A, supporting up to 55 directly connected current sensors. Its 1 ms recording interval is ideal for capturing fast-changing signals, while the 7" TFT display provides clear, real-time data visualization for easy on-site monitoring. With the flexibility to run for hours on battery power, the LR8450-01 ensures continuous logging for both stationery and mobile testing. Data can be stored on SD cards or USB sticks, and retrieval is made easy through its Gigabit-LAN connector. The logger also features a DC input for additional supply power flexibility. If no wireless modules are used, the logger can be controlled wirelessly from a PC, allowing it to be placed in restricted or hard-to-access areas. Whether monitoring electric vehicles or managing complex industrial systems, the LR8450-01 sets the standard for precision and adaptability in data logging.

€2,088.00*