Key Specifications

  • Max. 10 voltage/temperature modules and up to 300 channels (using M7100 and M7102) 
  • Max. 4 power modules and up to 12 power channels (using M7103) 
  • Max. update interval 5 ms 
  • High voltage logging up to 2000 VDC and current logging with HIOKI current sensors – rating 2 A to 2000 A 
  • Data transfer via TCP (LAN) - Integrated alarms, trigger in/out and pulse/logic in 

Unique Advantages

  • Logging of temperatures and voltages, 1500 VDC / CAT II isolation to earth with M7100
  • High-accuracy power logging with M7103 
  • High voltage logging (2000 VDC, 1000 VAC) with M7103 
  • Wide variety of HIOKI current sensors for a reliable high-precision current logging 

Typical Applications

  • Charge/discharge testing during cell formation and ageing 
  • Charge/discharge testing during development of battery modules and battery packs
  • Development and optimization of Battery Management Systems (BMS) 
  • Development and optimization of Thermal Management Systems of batteries 
  • Quality inspection of PV string inverters during production 

Detailed Product Overview

The versatile, modular data logger LR8101 can be used in combination with a variety of modules. It is therefore the perfect solution for integration in applications requiring multiple channels and recording intervals as short as 5 ms. The logger can be installed in a 19” rack with an optional rack-mount kit. The LR8101 can be controlled via Gennect One or the freeof-charge Logger Utility software. Additionally, the logger provides several inputs and outputs for alarms, triggers and pulse signals. The enhanced noise resistance ensures accurate and reliable measurements. All available modules can be combined in one system setup, with the main two measurement objectives being power logging and voltage/temperature logging. 

Voltage & Temperature logging with the LR8101

The LR8101 Data Logger can be combined with up to ten M7100 or M7102 modules. The system provides utmost flexibility as it offers the possibility to choose the type and number of modules to exactly fit the test requirements.

In combination with the module M7100 the logger can capture up to 150 channels at 5 ms update interval. With an isolation to Earth of 1500 VDC, CAT II measurements of voltages and temperatures of 800 V and even 1200 V batteries can be performed safely. 

When combined with module M7102 the logger offers up to 300 channels at 10 ms update interval. With an isolation of 600 VDC, CAT II it is the perfect solution for data logging of 400 V batteries. Besides voltage, both modules offer the possibility to capture temperature signals using thermocouples. 

Power logging with the LR8101

When adding the M1100 AC power supply module, up to four M7103 Power Measurement Modules can be connected offering a total of 12 channels for long-term high-precision logging of power. Alternatively, the M7103 can be used to measure voltages and currents. The voltage input channels offer direct measurement of voltages of up to 2000 VDC, 1000 VAC. Long-term current logging is possible with any of the high-precision HIOKI current sensors with an ME15W connector. The sensors are powered by the logger and do not require an external power supply.

Related products

L1012
L1012 - DC Power cable for LR8450, LR810x, MR8875 and MR8880
DC Power cable, 2 m, unprocessed ends, for LR8450, LR8450-01, LR8101, LR8102, MR8875 and MR8880

€48.00*
M1100
HIOKI M1100 - AC Power Supply Module for M7103 Power Module
AC power supply module for the M7103 power measurement module ensuring stable operation within LR810x data logger systems. HIOKI M1100 available now.

Z4001
Z4001 - SD Memory Card 2GB
The HIOKI Z4001 SD memory card provides 2 GB of industrial-grade storage, making it ideal for use with the HIOKI PW3360 Power Logger and similar products.

€138.00*
Z4003
Z4003 - SD Memory Card 8GB
The HIOKI Z4003 SD memory card is designed for use with Hioki instruments that support SD memory cards. With a storage capacity of 8 GB, it is ideal for data logging.

€368.00*
Z4006
HIOKI Z4006 - USB-stick 16GB
The Z4006 USB drive is designed for use with HIOKI instruments that support USB storage devices. With a storage capacity of 16 GB, it provides ample space for data logging.

€618.00*
9642
9642 LAN CABLE
LAN cable, straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m length, for the Memory HiCorder, LR8400 series, and similar products

€58.00*

Model Variants

LR8102
HIOKI LR8102 - Modular multi-channel Data Logger for system integration, optical sync, UDP, CAN
Modular multi-channel data logger for system integration with CAN and UDP support for synchronized data acquisition. HIOKI LR8102 available from HIOKI Europe.

Modules

M7100
M7100 - Voltage/temperature module for main unit LR8101 or LR8102
Voltage/temperature module for LR8101 and LR8102 Data Logger, 100 VDC channel input, 300 VDC channel to channel isolation, 1500 VDC CATII isolation to earth, 15 channels, max. update interval 5 ms 

€2,168.00*
M7102
M7102 - 30-channel voltage / temperature module for LR810x Data Logger Series
Voltage/temperature module for LR8101 and LR8102 Data Logger, isolation to earth 600 VDC CATII, 30 channels, max. update interval 10 ms, for 19” rack systems 

€1,998.00*
M7103
HIOKI M7103 - 3-channel power measurement module for LR810x Data Logger Series
3-channel power measurement module for LR810x Data Logger Series enabling synchronized power logging in modular measurement systems. HIOKI M7103 available now.