Product information "CM7290 - Display unit for current clamps (CT7600 and CT7700 series)"
The CM7290 is the display and output unit for the CT7600 and CT7700 series AC/DC current sensors, providing a stand-alone clamp-on meter for field use or enabling waveform signals to be output to a Hioki chart recorder or logger for further analysis.
Power supply and signal output for CT7000 series current sensor
Simultaneous dual display of measured values, frequency and output rate
Four output formats to output data to logger or other devices (via display unit)
Supports AC adapter, AA alkaline batteries and external power supply
The L9095 is a versatile output cable for connecting Hioki products with 3.5mm phone jacks to Hioki products with BNC terminal. Technical Data: Length: 1.5 m Connectors: two pole phone jack (3.5 mm), BNC male Compatible Hioki products: Loggers with BNC terminals, Devices with 3.5 mm phone connector output (CM7290, CM7291, FT3424, FT3425)
The Hioki CT7642 is a high-capacity AC/DC current sensor capable of measuring currents up to 2000 A. It operates over a wide frequency range from DC to 10 kHz, making it ideal for power electronics and waveform analysis. With a large conductor diameter of 55 mm, it is designed for industrial applications requiring precise, high-current measurements.The sensor provides high accuracy of ±1.5% for DC measurements and maintains performance across varied environmental conditions. Compatible with Hioki's Memory Recorders and data loggers, the CT7642 ensures reliable data acquisition for long-term monitoring.Technical Information:Measurement range: 2000 A AC/DC Frequency range: DC to 10 kHz Maximum conductor diameter: 55 mm Accuracy: ±1.5% for DC (45 Hz to 66 Hz) Operating temperature: −25°C to 65°C Safety category: CAT III 1000 V / CAT IV 600 VOutput connector: HIOKI PL14
The Hioki CT7631 is a high-performance AC/DC current sensor designed for accurate measurements up to 600 A. It operates across a wide frequency range, from DC to 10 kHz, making it ideal for a variety of applications including waveform analysis and current monitoring in power electronics. With a 33 mm conductor diameter and excellent safety ratings (CAT III 1000 V / CAT IV 600 V), it ensures reliable performance in both industrial and laboratory environments. The CT7631 is compatible with Hioki’s Memory Recorders and data loggers for efficient recording and analysis. Technical Information: Measurement range: 600 A AC/DC Frequency range: DC to 10 kHz Maximum conductor diameter: 33 mm Safety Category: CAT III 1000 V / CAT IV 600 V Output connector: HIOKI PL14 Typical accuracy: ±2.0% rdg. (45 Hz to 66 Hz) Operating temperature: −25°C to 65°C Dust and water resistance: IP40
The Hioki CT7731 is a versatile AC/DC current sensor designed for accurate measurements up to 100 A. With a wide frequency range from DC to 5 kHz, it is perfect for waveform analysis and real-time monitoring in various applications. The CT7731’s compact design and 33 mm conductor diameter allow for easy installation in confined spaces. It features high precision with an accuracy of ±1.0% for DC measurements and ensures reliable performance in fluctuating temperature conditions. The sensor is compatible with Hioki's Memory Memory recorder and data loggers for efficient data collection and analysis. Technical Information: Measurement range: 100 A AC/DC Frequency range: DC to 5 kHz Maximum conductor diameter: 33 mm Accuracy: ±1.0% for DC (45 Hz to 66 Hz) Operating temperature: −25°C to 65°C Safety category: CAT III 1000 V / CAT IV 600 V Output connector: HIOKI PL14
The CT7742 is an advanced AC/DC current sensor with auto-zero functionality, providing stable and precise measurements over time by compensating for offset drift. Technical Details: Rated current: 2000 A AC/DC Frequency range: DC to 5 kHz Amplitude accuracy: ±1.5% rdg, ±0.5% f.s. Diameter of conductors: 55 mm (2.17 in.) Cable length: 2.5 m (8.2 ft.) Operating temperature: -25°C to 65°C (-13°F to 149°F) CAT: IV 600 V, CAT III 1000 V Output terminal: PL14
The Hioki CT7736 is a high-performance AC/DC current sensor capable of measuring currents up to 600 A. With a frequency range from DC to 5 kHz, it is ideal for waveform analysis and high-current applications. The sensor features a compact design with a 33 mm conductor diameter, making it easy to install in various environments.Offering high accuracy of ±2.0% for DC measurements, the CT7736 is built for stable performance in fluctuating temperatures. It is compatible with Hioki's Memory Recorders and data loggers for precise and efficient data collection. Technical Information: Measurement range: 600 A AC/DCFrequency range: DC to 5 kHz Maximum conductor diameter: 33 mm Accuracy: ±2.0% for DC (45 Hz to 66 Hz) Operating temperature: −25°C to 65°CSafety category: CAT III 1000 V / CAT IV 600 V Output connector: HIOKI PL14
The 9234 is a printerpaper for MR8880 (PRINTER UNIT MR9000 required) and 8860, 8861, 8420, 8421, 8422, 8807, 8808, 8714, 8715 memory recorders. Technical Details:Roll type A6 width 112 mm × 18 m 10 rolls/set
The MR9000 Printer Unit is designed for use with the Hioki MR8880-20 Memory recorder, enabling easy printouts of measurement results. This compact and efficient printer offers precise waveform documentation directly from the connected Memory HiCorder, making it ideal for fieldwork and quick data review. The MR9000 ensures seamless integration with your HiCorder, delivering accurate and reliable outputs for all your measurement needs. Technical Information: Compatible devices: Hioki MR8880-20 Memory HiCorder Usable recording paper: 9234 Recording Paper Recording width: 104 mm (832-dot resolution), waveform section width 100 mmRecording speed: Max 1 cm/s Paper feed accuracy: ±3% (at 25°C, 60% RH)
The Hioki MR8870-20 Data Recorder is a versatile, compact oscilloscope-like device designed for high-speed waveform recording and long-term RMS data capture. It features isolated inputs for safe measurement of power lines, and its real-time data-saving functionality ensures continuous monitoring with minimal interruptions.With up to 1 MS/s sampling rate and the ability to record fluctuations in RMS data, the MR8870-20 is ideal for applications such as motor startup analysis, inverter output waveform monitoring, and CB timing measurements. Its portable design makes it easy to use on-site. Technical Details: Channels: 2 analog, 4 logic channels Max Sampling Rate: 1 MS/s (1 µs) Memory Capacity: 12 bits × 2 M-Words/channel Storage: CF card (up to 2 GB, FAT/FAT32) Display: 4.3-inch TFT color LCD Operating Temperature: 0°C to 40°C Power Supply: AC adapter (100–240 V), Battery Pack 9780 Dimensions: 176 mm (W) × 101 mm (H) × 41 mm (D) Weight: 600 g (with battery pack)
Z1002 ist ein Universalnetzteil für Netzspannungen von 100 V bis 240 V AC, 50/60 Hz, das 12V DC, 5,25A max (63W) zur Verfügung stellt. Es ist geeignet für die Hioki-Produkte CT9557, MR8875, MR8880, PW3198, PQ3100, PQ3198.Technische Details: Eingangsbereich: 100VAC bis 240VAC Ausgang: 12VDC, 5,25A, Pmax 63W Restwelligkeit & Rauschen: 100mVpp DC-Stecker: gewinkelter Hohlstecker 5,5mm (Innenmaß 2,5mm)
The power cable L1012 is designed to provide power through the DC input of compatible
devices. Measuring approximately 2 meters (6.6 feet) in length, it features unprocessed ends
for flexible integration into various setups. This cable is compatible with the LR8101 and
LR8102 Data Loggers, LR8450 and LR8450-01 Data Loggers, as well as the MR8880 and
MR8875 Memory Recorders, offering a versatile solution for powering your equipment in the
field or stationary configurations.Technical information:Length: approx. 2 m. Plug: angled Note: Can substitude L9500
The 9445-02 is an accessory AC adapter compatible with a wide range of Hioki products. It includes interchangeable plug heads, allowing it to adapt easily to international power outlets. Technical details: Type: Wall Mount AC plug head types: UL, CEE, BS, SAA, CCCInput range: 100VAC to 240VAC Output: 9VDC, 1.2A, Pmax 10.8WRipple & noise: 100mVpp DC connector: angled EIAJ-3 plug O.D. 4.75mm, I.D. 1.7mmPossible products: 283, 3284, 3285, 3290, 3290-10, 3540, 3664, FT3470-51, FT3470-52, SS7012
The CT7131 AC Current Sensor is a versatile tool designed for accurate AC current measurements in various industrial applications. With a measurement range of up to 100 A, it provides reliable and precise performance for power analysis and current monitoring. Its compact design ensures easy handling and integration with Hioki measuring instruments, making it ideal for professionals seeking dependable measurement solutions. Technical Specifications: Measurement Range: 100 A ACFrequency Range: 40 Hz to 5 kHz Basic Accuracy: ±0.3% rdg.±0.02% f.s. Maximum Conductor Diameter: 15 mm Operating Temperature: -10°C to 50°C Cable Length: 2.5 mSafety Category: 300 V CAT III Output Connector Type: Hioki PL14 connector
Compact 2-channel data logger, AC current logging with BNC current sensors, Bluetooth,
max. 500 000 data points/channel, AC, DC or battery operation Banner Specs: 2 channels for BNC current sensors 500 mA - 2000 A AC Bluetooth data transfer Internal memory: Up to 500 000 data points per channel Power supply with AA alkaline batteries, AC adapter, external DC power supply USPs: Precise current measurement with HIOKI current sensors Applications: High-accuracy long-term current logging in confined spaces where wireless data
acquisition and transfer is required
Product In detail:The compact LR8513 Wireless Clamp Logger is a 2-channel data logger to record AC load
and leak currents. A wide variety of current sensors can be connected to the logger’s BNC
inputs, allowing current measurements from 500 mA to 2000 A AC. The logger fits neatly inside
distribution panels, enabling seamless external monitoring. Power measurements can be
easily conducted by setting the voltage and power factor. Thanks to the Bluetooth® connectivity data can be easily downloaded to tablets or computers.
Up to 500,000 data points per channel can be stored in the internal memory, making it ideal
for long-term monitoring and analysis. The LR8513 can be powered with an optional AC adapter, AA alkaline batteries or with an
external DC power supply.
The Hioki MR8901 is a 4-channel analog input module designed for use with Hioki Memory Recorders. It allows precise voltage measurement across a wide range of frequencies, making it ideal for capturing fast transients and DC signals. With a maximum sampling rate of 500 kS/s and an integrated 16-bit A/D converter, it ensures high-resolution data acquisition.Technical Details:Channels: 4, voltage measurement Input Connectors: Isolated BNC (input resistance 1 MΩ, input capacitance 10 pF) Sampling Rate: 500 kS/s Measurement Range: 5 mV to 10 V/divLow-pass Filter: 5/50/500 Hz, 5 kHz Resolution: 1/1250 of measurement range (16-bit A/D converter) Accuracy: ±0.5% of full scaleFrequency Characteristics: DC to 100 kHz (-3 dB) Input Coupling: DC/GND Max Allowable Input: 150 V DC Dimensions: 119.5 mm (W) × 18.8 mm (H) × 151.5 mm (D)Weight: 180 g (6.3 oz)
The Z1000 Battery pack is a NiMH type recharchable battery for the MR8880, LR8400 series products.
It charges when installed in the main unit. Product details: Rating: 7.2V, 4500mAh Weight: 0.37 kg
CT7046 - AC Flexible Current Sensor
The CT7046 AC Flexible Current Sensor is designed for high-current measurements with a larger diameter to accommodate broader conductors. It provides reliable performance over a wide frequency range. Technical Details: Rated current: 6000 A AC Frequency range: 10 Hz to 50 kHz Amplitude accuracy: ±1.5% rdg, ±0.25% f.s. Diameter of conductors: 254 mm (10.00 in.) Cable length: 2.3 m, 0.2 m³ (7.55 ft., 0.66 ft.) Operating temperature: -25°C to 65°C (-13°F to 149°F) CAT: IV 600 V, III 1000 V Output terminal: PL14
The MR8880 is a 4 channel portable data acquisition system (DAQ) with a maximum sampling rate of 1Msamples/s on all analog channels simultaneously.
It has 4 analog direct input channels for voltages up to 600V and 8 logic channels.Technical Details: Complies CAT III 600V isolation for direct measure of 480V power line 4 complete isolated channels Operating temperature range of -10°C to 50°C Built to withstand mechanical shocks and vibrations PRESET function A memory capacity of 14bit × 1 M words/ch (1 word = 2 bytes)
The Hioki MR8875 Memory Recorder is a high-speed, multi-channel logger designed for long-term data recording and real-time waveform monitoring. It supports various input modules for mixed signal measurement, including voltage, temperature, strain, and CAN signals, with a sampling period as short as 2 µs. Its robust design is suitable for harsh environments, making it ideal for applications such as battery evaluation, motor testing, and power equipment analysis. Technical Details: Channels: Up to 60 channels with input modulesSampling Rate: 500 kS/sMemory Capacity: 32 MW (64 MB) Display: 8.4-inch TFT color LCD Storage: SD card, USB memory stick Dimensions: 298 mm × 224 mm × 84 mmWeight: 2.4 kg (excluding modules)
The Hioki MR8904 is a dual-port CAN (Controller Area Network) input module designed to interface with Memory recorder. It supports high-speed, low-speed, and single-wire CAN configurations, making it versatile for automotive and industrial applications. This module enables the analysis of up to 15 analog and 16 logic channels from CAN signals, providing precise data extraction and logging with fast response times. Technical Details:Input CAN Port: 2 ports, D-sub 9-pin male connectors Standards: ISO 11898 CAN 2.0b, ISO 11898-1, -2, -3, SAE J2411Interface: High-speed, low-speed, or single-wire CAN (selectable per port) Transmit ACK: ON/OFF for CAN signal acknowledgment Terminator: ON/OFF, 120 Ω built-in resistance Baud Rate: 50 kbps to 1 Mbps (high-speed), 10 kbps to 125 kbps (low-speed), 10 kbps to 83.3 kbps (single-wire) Analyzed Output Channels: Up to 15 analog and 16 logic channelsSignal Form: 1-bit to 32-bit signals (analog and logic) Response Time: Within 200 µs of receiving CAN message Dimensions: 119.5 mm (W) × 18.8 mm (H) × 151.5 mm (D)Weight: 185 g
The Hioki MR8902 is a 15-channel analog input module that supports both voltage and temperature measurements. It's designed for use with Memory recorder, offering flexibility for mixed-signal data capture across different types of sensors. With high-resolution measurements and customizable filtering, it’s ideal for applications requiring precise, multi-channel monitoring. This module offers robust performance for both voltage and temperature measurements in demanding applications.Technical Details: Channels: 15, for voltage/temperature measurementInput Connectors: Push button terminal (voltage/thermocouple) Voltage Measurement Ranges: 500 µV to 5 V/div (9 ranges) Temperature Measurement: Thermocouple types K, J, E, T, N, R, S, B, WRe5-26 Resolution: 1/1000 of measurement range (16-bit A/D converter) Digital Filter: 50 Hz, 60 Hz, or OFF Data Refresh Rate: 10 ms to 2 s (depending on filter settings) Max Allowable Input: 100 V DC Dimensions: 119.5 mm (W) × 18.8 mm (H) × 184.8 mm (D) Weight: 190 g
The CT7116 is designed for precise leakage current measurements with high accuracy. It supports BNC conversion for versatile applications. Technical Details: Rated current: 6 A AC Frequency range: 40 Hz to 5 kHz Amplitude accuracy: ±1.0% rdg, ±0.05% f.s. Diameter of conductors: 40 mm (1.57 in.) Cable length: 2.5 m (8.20 ft.) Operating temperature: -25°C to 65°C (-13°F to 149°F) Output terminal: PL14
The Hioki MR8905 is a 2-channel input module designed for high-precision voltage and RMS measurements. It allows switching between instantaneous values and AC RMS values, making it ideal for applications in power analysis and waveform monitoring. With a high sampling rate and integrated low-pass filter, the module ensures accurate data acquisition. Technical Details: Channels: 2, switchable between instantaneous value and AC RMS valueInput terminals: Banana jacks (CAT II 1000 V AC & DC, CAT III 600 V AC & DC) Measurement range: 500 mV to 50 V/div, 7 ranges Low-pass filter: 5/50/500/5 kHz, OFF Resolution: 1/1250 of the measurement range (16-bit A/D converter) Sampling rate: 500 kS/s (simultaneous for 2 channels) Accuracy: ±0.5% f.s. (with 5 Hz filter ON) RMS accuracy: ±1.5% f.s. (30 Hz to 1 kHz), ±3% f.s. (1 kHz to 10 kHz) Input coupling: DC/AC RMS/GNDMaximum input: 1000 V DC, 700 V AC Dimensions: 119.5 mm × 18.8 mm × 151.5 mm Weight: 185 g
SSD Unit for MR6000, 256 GB, factory option, allows real-time recording at maximum 20
MS/s In detail:256 GB SSD Unit for the MR6000 Memory Recorder, available as a factory-installed option.
This unit expands the built-in storage capacity and enables real-time recording directly to the
SSD with a maximum sampling speed of 20 MS/s, when used with the MR6000-01 model.
The SSD option must be ordered together with the main instrument at the time of purchase.
For installation at a later stage, the main instrument must be sent to a HIOKI service center.
The CT7126 AC Current Sensor is a compact, reliable solution for accurate AC current measurement. Ideal for power measurement and analysis, the sensor is designed to meet the needs of various industrial applications. Its compact form factor allows for easy handling, while its durable construction ensures precise and consistent performance. Technical Specifications: Measurement Range: 60 A AC Frequency Range: 40 Hz to 5 kHzBasic Accuracy: ±0.3% rdg. ±0.01% f.s. Maximum Conductor Diameter: 15 mm Operating Temperature: -10°C to 50°C Cable Length: 2.5 m Safety Category: 300 V CAT III Output connector: Hioki PL14 Connector
The C1004 is a rugged rolling hard case designed specifically for the MR8875. It features built-in wheels and a telescoping handle, providing excellent mobility for field use. The case includes dedicated compartments for both the main unit and additional accessories, ensuring secure and organized storage. This robust trunk-style case offers exceptional protection for your equipment during transport.Technical Information: Length: 5570 mm Width: 2380 mm Height: 3760 mm Weight: 6.3 kg Type: Rolling hard case with wheelsCompatibility: MR8875, includes compartment for accessories
The Z5021 Probe Power Unit for the MR6000 Memory Recorder is a factory-installed option
designed to provide power to up to eight current probes or clamps from the CT670x or 327x
Series. Additionally, the Z5021 supports up to four CT6710 or CT6711 current clamps. For
applications requiring higher voltages the Z5021 can power up to eight 9322 or up to three
P9000 Differential Probes. It delivers a stable output voltage of ±12 V DC and a rated output current of 0.6 A per
terminal. The Z5021 must be ordered together with the main instrument at the time of purchase. For
an installation at a later stage, the main instrument needs to be sent to a HIOKI service
center.
The Hioki MR8903 is a 4-channel input module designed for voltage and strain measurements, ideal for precision data acquisition in industrial and research environments. It supports a wide range of strain gauges and offers electronic auto-balancing, ensuring high accuracy in both dynamic and static measurements. The module features customizable low-pass filters and provides high-resolution data capture with a 16-bit A/D converter. Technical Details: Channels: 4, selectable for voltage/strain measurement Voltage Measurement Range: 50 µV to 1000 µV/div Strain Measurement Range: 20 µε to 1000 µε/div Input Connectors: Strain gauge converter, Bridge resistance: 120 Ω to 1 kΩ Max Sampling Rate: 200 kS/s Low-pass Filter: 5/10/100 Hz, 1 kHz, OFFResolution: 1/1250 of measurement range (16-bit A/D converter) Max Allowable Input: 5 V DC Dimensions: 119.5 mm (W) × 18.8 mm (H) × 151.5 mm (D)Weight: 173 g
The Z1003 is a 7.2 V DC, 4500mAh Nickel-Metal Hydride (Ni-MH) rechargeable battery pack designed for use with Hioki devices such as the MR8875, PQ3198/PW3198, and PQ3100. It provides reliable power, ensuring extended operation in the field and in demanding environments. Technical Details: Battery Type: Ni-MH Voltage: 7.2 V DC Capacity: 4500mAh Compatible Devices: MR8875, PQ3198/PW3198, PQ3100
The CT7044 AC Flexible Current Sensor is ideal for measuring high currents over a wide frequency range. It features a flexible design with a 100 mm diameter, making it suitable for large conductors in tight spaces. Technical Details: Rated current: 6000 A AC Frequency range: 10 Hz to 50 kHz Amplitude accuracy: ±1.5% rdg, ±0.25% f.s. Diameter of conductors: 100 mm (3.94 in.) Cable length: 2.3 m, 0.2 m³ (7.55 ft., 0.66 ft.) Operating temperature: -25°C to
65°C (-13°F to 149°F) CAT: IV 600 V, III 1000 V Output terminal: PL14
The CT7136 AC Current Sensor is designed for high-accuracy current measurements up to 600 A, making it ideal for industrial applications where large currents and high precision are required. Its robust build and wide frequency range ensure reliable performance, even in demanding environments. The sensor easily integrates with Hioki measuring instruments, allowing for seamless data collection and analysis. Technical Specifications: Measurement Range: 600 A ACFrequency Range: 40 Hz to 5 kHz Accuracy / Amplitude Accuracy: ±0.3% rdg. ±0.01% f.s. Maximum Conductor Diameter: 46 mm Operating Temperature: -10°C to 50°C Cable Length: 2.5 m Safety Category: 1000 V CAT III, 600 V CAT IV Output Connector Type: Hioki PL14 connector
Banner Specs: 8 slots for modules with up to 32 isolated analog channels 15 different input and 3 output modules High-speed data sampling with 200 MS/s Real-time data saving with up to 20 MS/s User-friendly software and touchscreen display Compatibility with a wide variety of HIOKI current sensors Applications: Testing and evaluation of railway, aerospace and automotive components including
electric vehicle motors, inverters, and battery systems Development and maintenance of renewable energy technologies, such as wind
turbines and solar panels - monitoring electrical outputs and mechanical performance Testing of household and industrial appliances by capturing high-speed transient
events and long-term trends Monitoring of SMPS (Switched-Mode Power Supply) output currents over extended
periods with high sampling rates Electric Vehicle (EV) motor shaft angle sensing thanks to its built-in resolver
calculation functionIn detail:The MR6000 Memory Recorder is a high-performance waveform recorder designed for
capturing high-speed, high-accuracy data across multiple channels. It is ideal for complex
applications such as inverter testing, ECU signal analysis, and monitoring physical
phenomena. Featuring user-friendly software, a touchscreen interface, and various
calculation and analysis functions, the MR6000 ensures precise and efficient data acquisition
for professionals in research, development, and industrial settings.Input and Output Modules: The MR6000 offers exceptional versatility with its plug-and-play modular design with 8 slots.
Modules can be easily swapped and are automatically recognized by the device. The
MR6000 supports 15 different input modules for various measurements, such as high voltage
monitoring up to 1000 VDC/700 VAC with the U8974, multi-channel configurations using the
U8975 for up to 32 channels, and high-speed applications with the U8978, which offers a
sampling rate of 200 MS/s. DC modules with 24-bit resolution allow ultra-precise voltage
measurements with a resolution of 0.1 µV. The MR6000 also supports three output modules, including pulse and waveform generation
for signal testing and simulation. The Arbitrary Waveform Generator Module U8793 allows users to program and generate custom waveforms, ideal for reproducing and simulating
anomalies. The free SF8000 software simplifies waveform creation by enabling direct data
input or formula-based design and supports noise simulation or multiplying waveforms for
advanced scenarios. Current Measurement: The MR6000 offers additional versatility by allowing the direct connection of HIOKI's highaccuracy current sensors. Wideband current probes like the CT6711 can be paired with
analog modules such as the U8978. The dedicated current modules U8977 and 8971
support precise measurement across a wide range of currents, working seamlessly with
high-precision clamps and sensors like the CT6841A or CT6904A. With these designated current modules, the MR6000 automatically recognizes, and powers
connected HIOKI sensors and clamps, ensuring an easy and efficient setup. HIOKI wideband
current probes with BNC and 2-pin LEMO connectors can also be powered via the Z5021
Probe Power Unit, which is available as a factory-installed option. In addition to powering current probes and clamps, the Z5021 Probe Power Unit can supply
power to up to eight differential probes. This significantly expands the MR6000’s capabilities
for high-voltage measurements, supporting voltages up to 2000 VDC and 1000 VAC. Data Handling: Equipped with advanced internal processing, the MR6000 enables fast data
saving and efficient handling, reducing downtime and enhancing productivity. For long-term
recording, the high-capacity SSD Unit U8332 option allows continuous data capture at high
sampling rates. The MR6000-01 model enables real-time data saving at speeds of up to 20
MS/s. User Interface: The MR6000 features a large 12.1-inch touchscreen with a user-friendly
interface. Its intuitive design makes it easy for users to view and analyze their data
effortlessly. Software Tools: The MR6000 offers comprehensive software analysis tools, including the
free MR6000 Viewer for data analysis, 9335 Wave Processor for waveform management,
GENNECT One for centralized control of up to 30 HIOKI instruments via LAN. In addition,
drivers for custom applications like LabVIEW and MATLAB are available. Models: The MR6000 is offered in two models: the standard MR6000 and the advanced
MR6000-01, which includes two additional features – real-time waveform calculation and
real-time data saving.
The real-time waveform calculation function enables users to monitor calculated results
instantly during measurements, providing immediate insights.The real-time saving function
allows data to be recorded at a maximum sampling rate of 20 MS/s directly onto an external
memory device. This feature offers several key benefits: Long-term recording with up to 20 MS/s Extended recording durations, limited only by the storage capacity of the external
device Record on the SSD, USB stick or choose any other device (via FTP)Data integrity with non-volatile memory ensures recorded data stays secure and
ready for retrieval, even when the device is powered off
The L9094 is a versatile output cable for connecting Hioki products with 3.5mm phone jacks to transmit analogue information to devices with banana jacks as inputs. Technical data: Length: 1.5 m Connectors: two pole phone jack (3.5 mm), banana plug 4 mm Compatible Hioki products: 3283, 3284, 3285, 3664, FT3406, FT3424, FT3425
The L9096 is an accessory cable for Hioki products such as FT3424, FT3425, CM7290, CM7291 to connect these devices to Hioki data recorder terminal blocks. Technical details: Length: 1.5m Connector: Ø3.5mm Wire ends: plain black/red sleeving
The Z5004 is a holding strap with magnet that can be used with LR85xx / LR5000 series data loggers, PD3259 phase detectors and similar products and DT42xx series digital multi-meters. Suitable for:DT4252 DT4253 DT4254 DT4255 DT4256 DT4261 DT4281 DT4282 PD3259 PQ3100 PQ3198