Electrochemical Measurement Solutions
Comprehensive understanding of material quality
Electrochemical measurements are vital for understanding and optimizing material properties in batteries, capacitors, and other energy devices. HIOKI’s solutions provide quantitative insight into conductivity, dispersion, and interface resistance - key parameters for performance and quality. The SA2634-KIT Slurry Analysis System evaluates slurry properties before coating, combining advanced software and precise hardware for standardized analysis. The RM2610 Electrode Resistance Measurement System isolates composite layer and interface resistances after coating to ensure consistent electrode quality. Complementary instruments like the IM3590 Impedance Analyzer expand electrochemical evaluation across research and production. Browse our solutions and contact us for more information.
20
%
IM3590
IM3590 - Impedance analyser
The IM3590 Chemical Impedance Analyzer is designed for precise measurement of electrochemical components and materials, including batteries and electric double-layer capacitors (EDLCs).
RM2610
RM2610 - Measurement System for LIB battery electrode sheets
Electrode Resistance Measurement System, isolates and quantifies the composite layer resistivity and the interface resistance between the composite layer and the aluminum or copper current collector foil of LIB electrode sheets in a single measurement
SA2634-KIT
SA2634-KIT - Slurry Analysis System for LiB Conductivity Evaluation
Key Specifications
Slurry conductivity and dispersion evaluation (DCR, R-ratio, Uniformity)Automated equivalent-circuit fitting For aqueous and NMP based slurries Impedance data from 4 Hz to 8 MHz Unique AdvantagesCombines frequency-sweep EIS with automated equivalent-circuit fitting for
quantitative slurry evaluationProvides three proprietary metrics (DCR, R-ratio, and Uniformity) for consistent
assessment of conductivity and dispersion Typical ApplicationsOptimization of slurry manufacturing conditions (e.g. mixing time, conductive agent
content, dispersant ratio) in R&D and production Material research and evaluation using electrical dispersion analysis and comparative
conductivity metricsQuality assurance and performance screening of lithium-ion battery slurries in
production environments Product Description
The SA2634-KIT Slurry Analysis System is a software-based solution that quantifies the
electrical characteristics of lithium-ion battery (LiB) slurries through impedance analysis. The
KIT includes the SA2634 analysis software, the IM3536 LCR Meter, the SA9002 Test Fixture,
and one pack each of disposable slurry sample containers SA9001 (for NMP-based slurries)
and SA9001-01 (for aqueous slurries). By combining these components, the system enables standardized and repeatable evaluation of slurry conductivity and dispersion across a wide
frequency range from 4 Hz to 8 MHz. Measurement and Analysis PrincipleUsing electrochemical impedance spectroscopy (EIS), the IM3536 acquires the impedance
spectrum of the slurry. The SA2634 software models this data with an equivalent circuit to
extract three proprietary parameters: DCR, representing the total resistance of the
conductive path; R-ratio, indicating the relative contribution of conductive additives within that
path; and Uniformity, reflecting the evenness of the conductive network distribution. Together, these metrics provide a quantitative understanding of how well conductive
additives are dispersed and connected within the slurry. They help engineers identify the
optimal ratio between active material and conductive agent, assess the homogeneity of
dispersion, and directly link electrical behavior to electrode performance.Measurement Process and Practical ApplicationFor each measurement, approximately 1 ml of slurry is dispensed into a disposable sample
holder. The SA9001 slurry sample container is used for N-Methyl-2-Pyrrolidone (NMP)-based
slurries, while the SA9001-01 is intended for aqueous (water-based) slurries. The filled
sample holder is placed into the SA9002 Test Fixture, a fixture developed specifically for this
measurement system, where it establishes a stable electrical connection to the IM3536 LCR
Meter. Once secured, the system performs an impedance sweep across a user-defined
frequency range between 4 Hz and 8 MHz. Each measurement takes approximately one
minute, minimizing changes in the slurry’s state during testing. By combining automated equivalent-circuit fitting with batch processing of up to 1,000
datasets, the SA2634 software significantly streamlines data handling and comparison
between multiple samples. Over time, accumulated measurement data provide traceable
reference values for long-term process control and quality assurance, enabling consistent
evaluation across R&D and production environments. The SA2634 system establishes a
standardized, quantitative framework for early-stage formulation studies, process
optimization, and quality control, helping maintain uniform electrode conductivity and
reproducibility from lab scale to mass production.
SA9001
SA9001 - Slurry sample container for NMP-based slurry measurement
Detailed Product OverviewThe SA9001 is used together with the SA9002 Test Fixture as part of HIOKI’s SA2634-KIT
Slurry Analysis System. Each pack contains 50 slurry sample containers (also referred to as
electrode cells) for impedance measurement of N-Methyl-2-Pyrrolidone (NMP)-based lithiumion battery slurries. The nickel-plated electrode surfaces provide durable, low-resistance
contact optimized for impedance analysis of NMP-based slurries. NMP-based slurries are mainly used in the development and production of cathode materials
such as Nickel-Cobalt-Manganese (NCM) and Nickel-Cobalt-Aluminum (NCA). The
performance of these electrodes strongly depends on the homogeneous dispersion of
conductive additives within the slurry. Because NMP effectively dissolves binder materials, it
enables uniform dispersion and coating, making impedance characterization a key tool for
process optimization. Each container holds approximately 1 ml of slurry and is intended for single use to avoid
cross-contamination between measurements. When mounted in the SA9002 Test Fixture, it
defines the electrode geometry and ensures consistent contact conditions for reproducible
impedance measurements. Although part of the SA2634-KIT Slurry Analysis System, the SA9001 sample containers can
also be purchased separately or used independently with other HIOKI LCR Meters and
impedance analyzers in combination with the SA9002 Test Fixture. The containers are
optimized for slurry materials; use with other conductive pastes may lead to different contact
characteristics and is not covered by HIOKI specifications.
SA9001-01
SA9001-01 - Slurry sample container for aqueous slurry measurement
Detailed Product OverviewThe SA9001-01 is used together with the SA9002 Test Fixture as part of HIOKI’s SA2634-
KIT Slurry Analysis System. Each pack contains 50 slurry sample containers (also referred to
as electrode cells) for impedance measurement of aqueous (water-based) lithium-ion battery
slurries. The gold-plated electrode surfaces provide corrosion-resistant, low-resistance
contact optimized for impedance analysis of aqueous slurries. Aqueous slurries are primarily used in the development and production of anode materials
such as graphite or silicon-based composites. Since these systems use water as a solvent
instead of N-Methyl-2-Pyrrolidone (NMP), they are environmentally safer and require
electrodes that maintain stable electrical properties even in the presence of moisture. Gold
plating prevents oxidation and ensures consistent measurement results over repeated use in
wet environments. Each container holds approximately 1 ml of slurry and is intended for single use to avoid
cross-contamination between measurements. When mounted in the SA9002 Test Fixture, it
defines the electrode geometry and ensures consistent contact conditions for reproducible
impedance measurements. Although part of the SA2634-KIT Slurry Analysis System, the SA9001-01 sample containers
can also be purchased separately or used independently with other HIOKI LCR Meters and
impedance analyzers in combination with the SA9002 Test Fixture. The containers are
optimized for slurry materials; use with other conductive pastes may lead to different contact
characteristics and is not covered by HIOKI specifications.
SA9002
SA9002 - Fixture for slurry measurement with IM3536
Detailed Product OverviewThe SA9002 Test Fixture is an integral component of HIOKI’s SA2634-KIT Slurry Analysis
System. It connects to the IM3536 LCR Meter via four BNC terminals and provides secure
mounting for the disposable Slurry Sample Containers (SA9001 or SA9001-01) containing
the slurry sample.Although part of the SA2634-KIT Slurry Analysis System, the SA9002 can also be purchased
separately as a replacement fixture or used independently with other HIOKI LCR Meters, the
IM3570 Impedance Analyzer or the IM3590 Chemical Impedance Analyzer in combination
with the disposable sample containers. This enables users to build customized measurement
setups tailored to their specific evaluation requirements. The SA9002 Test Fixture and the associated sample containers are optimized for use with
slurry materials. The nickel- or gold-plated electrode surfaces of the containers ensure stable
contact and reproducible impedance results under defined slurry conditions. Use with other
pastes or conductive materials may result in different contact characteristics and is not
covered by HIOKI specifications.