PW3365-20 - Non-contact power logger with voltage and current sensors
Non-contact 3-phase 4-wire Clamp-on Power Logger, 90 V to 520 V at 50/60 Hz, 50 mA to 5 kA using external current sensors, harmonic measurement up to the 13th order, SD memory card slot (max. 8 GB), LAN and USB interface
€3,058.00*
Content:
1 Each
In stock, delivery time: Ready for dispatch
Available stock:
2
Product details
Product number:
PW3365-20
EAN:
4536036002207
Width:
480 mm
Height:
1000 mm
Weight:
2.72 kg
Product information "PW3365-20 - Non-contact power logger with voltage and current sensors"
Banner Specs:
By selecting the appropriate current sensor, the PW3365 can be tailored for specific power
monitoring needs, ensuring reliable, high-precision energy measurements in various
environments.
Delivering all essential measurements, it supports precise monitoring of single-phase to 3-
phase 4-wire systems. Whether for audits or continuous monitoring, the PW3365 offers
dependable insights that drive energy savings and operational improvements.
- Non-contact voltage and current measurement
- Voltage measurement from 90 V to 520 V at 50/60 Hz
- Current measurement from 50 mA to 5 kA using external sensors
- Independent long-term data logging to SD card
USPs:
- Non-contact voltage sensing
Applications:
- Energy Efficiency Optimization
- Long-term power consumption monitoring
- Equipment diagnostics and checks
In detail:
The PW3365 Clamp-on Power Logger measures voltages and currents safely and efficiently without direct contact with live circuits. Its innovative voltage clamp sensors attach easily to insulated wires, enabling non-intrusive measurements. Operating effectively within a voltage range of 90 to 520 V and a current range of 50 mA to 5 kA at 50/60 Hz, it minimizes risks like short circuits and electrical hazards. This makes it ideal for monitoring power consumption and demand across various installations, from single-phase to 3-phase 4-wire systems.
The PW3365 Clamp-on Power Logger measures voltages and currents safely and efficiently without direct contact with live circuits. Its innovative voltage clamp sensors attach easily to insulated wires, enabling non-intrusive measurements. Operating effectively within a voltage range of 90 to 520 V and a current range of 50 mA to 5 kA at 50/60 Hz, it minimizes risks like short circuits and electrical hazards. This makes it ideal for monitoring power consumption and demand across various installations, from single-phase to 3-phase 4-wire systems.
Thanks to its compact design, the PW3365 fits seamlessly into confined spaces, such as
connection cabinets or switchboards. It provides precise readings and detailed insights to
help identify and reduce energy losses. Equipped with an 8 GB SD memory card, it supports
long-term stand-alone data logging. This versatility makes it suitable for energy audits, load
studies, and equipment inspections, highlighting opportunities to enhance efficiency and cut
costs.
To perform measurements, the PW3365 requires AC current sensors with a BNC connector.
These current sensors are not included with the logger and are sold separately.
The following Hioki current sensors are compatible with the PW3365:
Model | Load current Leak current | Leak current | |||||
---|---|---|---|---|---|---|---|
9660 | 9661 | 9669 | 9694 | CT9667 | 9657-10 | 9675 | |
Description | AC Clamp-on Sensor 100 A | AC Clamp-on Sensor 500 A | AC Clamp-on Sensor 1000 A | AC Clamp-on Sensor 5 A | AC Flexible Current Sensor 5000 A | AC Clamp-on leak sensor 10 A | AC Clamp-on leak sensor 10 A |
Bandwidth | 40 Hz bis 5 kHz | 10 Hz bis 20 kHz | 40 Hz bis 5 kHz | ||||
Rated current | 100 A | 500 A | 1000 A | 5 A | 500 A / 5000 A | 10 A | |
Output rate | 1 mV/A | 0.5 mV/A | 10 mV/A | 1 mV/A (500 A) 0.1 mV/A (5000 A) |
100 mV/A | ||
Basic accuracy | ±0.3% / ±1.0% | ±1.0% | ±0.3% | ±2.0% | ±1.0% | ±1.0% | |
Max. core diameter | 15 mm | 46 mm | 55 mm | 15 mm | 100 mm bis 254 mm | 40 mm | 30 mm |
The PW3365 supports both load current and leak current logging, making it ideal for
comprehensive power analysis. Load current logging captures the power consumption of
machines, electrical panels, or entire facilities and helps identify inefficiencies. Leak current
logging detects unintended leakage caused by insulation faults, incorrect wiring, or aging
equipment. Monitoring these currents helps prevent electrical hazards, reduce fire risk, and
ensure compliance with safety standards. This combination makes the PW3365 a valuable
tool for spotting inefficiencies and detecting faults before they lead to failures.
The PW3365 comes with the Z1008 AC adapter for operation where mains power is
available. If no outlet is accessible, the optional PW9002 Battery Set, which mounts on the
back of the instrument, provides up to 3 hours of battery-powered operation. These flexible
power options ensure reliable performance in both fixed installations and mobile applications.
Designed for energy consultants, facility managers, and service engineers, the PW3365 is a
safe, reliable, and user-friendly solution for energy monitoring. Its compact form factor allows
easy deployment in tight spaces, while non-contact voltage probes simplify setup and
eliminate the risk of short circuits. Supports real-time monitoring via LAN and enables
seamless connectivity with the free HIOKI Gennect One PC software, ensuring efficient and
continuous power management.
- PW3365-20
- 1 set Safety Voltage Sensor PW9020
- AC adapter Z1008
- USB cable Instruction manual Measurement guide
- 4x Color clip (red, yellow, blue and white)
- 10x Spiral tubes in black (cord bundling for current sensors and voltage sensors)
-
Product brochure with data sheet, clamp on power logger PW3365 (English)8,286 KB pdf
-
Product Catalog with data sheet, Field Measuring Instruments (English)40,005 KB pdf
-
Product brochure with datasheet, Selection guide, Power Quality Analyzers / Power Loggers (English)3,584 KB pdf
-
Instruction Manual, CLAMP ON POWER LOGGER PW3365-20 (English)4,947 KB pdf
-
Instruction Manual, CLAMP ON POWER LOGGER PW3365-20 (German)6,420 KB pdf
-
Instruction Manual, CLAMP ON POWER LOGGER PW3365-20 (French)6,470 KB pdf
-
Product Brochure, AC FLEXIBLE CURRENT SENSOR CT9667 (English)1,746 KB pdf